期刊文献+

探讨凹型建筑外立面火灾竖向蔓延 被引量:6

Vertical spread of facade fire on concave building
下载PDF
导出
摘要 选取10起典型外立面火灾案例进行分析,结合FDS软件进行建模,模拟凹型平面建筑外立面火灾,分析火场温度、烟气蔓延、CO浓度,模拟结果与矩形平面模型(标准模型)、不同进深的凹型模型、不同面宽的凹型模型模拟结果进行对比,研究凹型平面建筑外立面火灾竖向蔓延的特点。凹型平面建筑进深的增加对烟气蔓延、火场温度并没有本质影响;面宽的增加使火场温度降低,烟气蔓延减缓。 Combined with model establishment by FI)S, ten cases of typical facade fire were selected to analyze the facade fire of the concave plane building. By measuring the value of fire tempera ture, smoke spread and concentration of CO, and comparing with the models of rectangular plane, concave model with different depths and concave model with different widths,the vertical fire spread of concave plane building was analyzed.Tbe increase of depth of concave has no essential effect on the smoke spread and the temperature of fire, but the increase of width can reduce tbe temperature of fire and the spread of smoke.
作者 唐虎潇 TANG Hu-xiao(Public security fire force academy, Yunnan Kunming 65020)
出处 《消防科学与技术》 CAS 北大核心 2017年第8期1055-1058,共4页 Fire Science and Technology
关键词 高层建筑 凹型建筑 外立面火灾 火灾蔓延 FDS high-rise building concave building facade fire fire spread FDS
  • 相关文献

参考文献8

二级参考文献19

  • 1李兆文,何嘉鹏,彭红圃.单一空间火灾三维场模拟[J].消防科学与技术,2005,24(1):22-25. 被引量:3
  • 2孙建军,李烈,路世昌,智会强.高层建筑管道井内烟气运动大涡模拟[J].中国安全科学学报,2006,16(9):40-44. 被引量:10
  • 3姜蓬,邱榕,蒋勇.基于数值模拟的某大厦特大火灾过程调查[J].燃烧科学与技术,2007,13(1):76-80. 被引量:28
  • 4GB 50045-95高层民用建筑设计防火规范,2005年版.
  • 5Zhang Jun, Shields T J, Silcock G W H. Effect of melting behaviour on upward flame spread of thermoplastics[J]. Fire and Materials, 1997, 21 (1) : 1-6.
  • 6Ohlemiller T J, Shields J, Butler K. Exploring the role of polymer melt viscosity in melt flow and flammability behaviour[C]// New Developments and Key Market Trends in Flame Retardancy. Lancaster, PA, 2000: 1- 28.
  • 7Sherratt Jo, Drysdale D. The effect of melt flow process on the fire behaviour of thermoplastics [C]//Inter Flame 2001 9th International Fire Science and Engineering Conference. Greenwich, London, 2001 : 149-150.
  • 8Butler K, Ohlemiller T J, Literis G T. A progress report on numerical modelling of experimental polymer melt flow behaviour[C]// International Interflam Conference lOth Proceedings. Edinburgh, Scotland, 2004 : 937-948.
  • 9ISO 9705. Fire Tests-Full-Scale Room Test for Surface Product[S]. Geneva: International Standards Organization (ISO). 1993.
  • 10international code council.2006 international building code[M].Whittier:international code council,inc.,2006.

共引文献88