通过试验对漳泽发电厂苏制ЕП - 6 70 -13.8/ 5 4 5KT型锅炉制粉系统三次风对炉内工况的影响进行了分析 ,提出了解决问题的方法。
This article conducts a analysis about the influence of furnace combustion dynamic caused by the tertiary air come from the pulverized coal system of the boiler imported from former USSR ЕП-670-13.8/545KT by means of testing, and puts forward the solution.