摘要
使用 D6 30单绞机对宽带数据电缆缆芯成缆绞合时 ,发现产品说明书提供的成缆节距参数与实际节距误差较大 ,为此 ,我们对该设备的成缆节距参数重新进行计算 ,并对其进行实践的验证。
It is found that there is a great difference between the laying up pitch given in the operating directions of D 630 Single Twist Cabling Machine and the real value. Therefor we made calculations again of the laying up pitch of D 630 Single Twist Cabling Machine and check up the calculated value by the real value. This article presents the process and result of the calculation of laying up pitch.
出处
《电线电缆》
北大核心
2002年第4期47-48,共2页
Wire & Cable
关键词
D630单绞机
成缆节距
计算
电线电缆
D 630 Single Twist Cabling Machine
laying up pitch
calculation
check up