期刊文献+

百万机组空预器两侧排烟温度偏差大原因分析及防范措施 被引量:2

Cause Analysis of the Large Deviation in the Exhaust Gas Temperature at the Two Sides of the Air Pre-Heater of the 1000 MW Unit and Precautionary Measures
下载PDF
导出
摘要 围绕某电厂2#炉排烟温度偏差大及排烟温度高的问题,从空预器运行数据及空预器内部可能发生堵塞等问题展开技术分析,找出两侧排烟温度偏差大的原因,并针对各类原因,提出了相应的控制措施。 In order to solve the problems of the large deviation in the exhaust gas temperature as well as the high temperature of the gas of the 2# boiler of a power plant,this paper introduces the technological analysis of the operating data of the air pre-heater and problems like block-ups in it. In addition,it introduces the causes of the large deviation in the exhaust gas temperature at its two sides as well as putting forward corresponding control measures.
作者 廖辉 关伟德
出处 《重庆电力高等专科学校学报》 2017年第4期31-34,共4页 Journal of Chongqing Electric Power College
关键词 超超临界机组 排烟温度 偏差 空预器堵塞 ultra-supercritical unit exhaust gas temperature deviation block-ups in the air pre-heater