期刊文献+

循环水中钾离子含量的测定方法 被引量:3

DETERMINATION METHOD FOR POTASSIUM ION IN CIRCULATE WATER
下载PDF
导出
摘要 循环水中的钾离子测定可采用火焰光度法。由于循环水中存在的钠、钙、镁等其他金属离子对测定有一定的干扰,因此,在测定过程中采用对比的方法,在制作标准曲线时加入干扰大的镁离子做本底液,再对每种干扰离子进行比对试验,即可从试验结果找出最佳的测定条件。 Potassium ion in the circulate water could be determined by flame photometry method, but metal ions in the circulate water such as sodium, calcium and magnesium could cause certain jamming on the potassium ion determination, and the comparison method was adoptedl Drawing of the standard curve with the reference liquid added by big jamming magnesium ion, comparison experiments were made by each jamming metal ion, and the best optimum test conditions were found from the experiments results.
作者 惠玉枝
出处 《齐鲁石油化工》 2017年第3期249-252,共4页 Qilu Petrochemical Technology
关键词 循环水 火焰光度法 基态 激发态 电磁辐射 circulate water flame photometry method ground state excited state electromagnetic radiation
  • 相关文献

同被引文献51

引证文献3

二级引证文献2