摘要
在特高压受电电网中,一次调频的作用愈加重要。大型燃煤机组担负着主要的一次调频作用,还有较多机组没有达到理想的性能指标,性能试验又较难发现问题。通过对考核机组的分析,提出了禁止与调频功率反向动作逻辑,提高调频能力的修正滑压曲线、修正前馈系数两类优化方案,供不同性能的机组选用。
In ultra-high voltage power gird receiver-side,primary frequency modulation became more and more important. Large scale coal-fire power is responsible for primary modulation,but many units cannot achieve expected performance,and problems barely can be detected by performance tests. By analyzing tested units,prohibition and frequency modulation counter action logic was indicated. Corrected sliding pressure curve,which increases frequency modulating ability,and corrected feedforward coefficient was provided. This could be referred by different kind of unit.
出处
《华电技术》
CAS
2017年第9期16-19,共4页
HUADIAN TECHNOLOGY
关键词
一次调频性能
控制逻辑优化
去除调频反逻辑
修正滑压曲线
前馈系数修正
primary frequency modulation performance
control logic optimum
frequency modulation removal counter logic
fixed sliding pressure curve
feedforward coefficient of correction