期刊文献+

直接空冷系统风机变频器群水冷系统研究

Direct air cooling system fan frequency converter group water cooling system study
下载PDF
导出
摘要 直接空冷系统变频器布置集中,夏季高温天气下变频器群运行时经常超温报警,影响电厂安全、稳定、高效运行。对变频器群超温报警原因进行分析,提出了外加水冷系统的解决方案,实际运行效果良好且节能环保,有效延长了变频器的使用寿命。 Direct air cooling system frequency converter usually aligned concentratedly,and often caused over temperature alarm in summer. After cause analysis,the plan that adds water cooling system was introduced. Actual operation proved that this plan is effective and able to save energy and prolong converter life-span.
作者 崔超
出处 《华电技术》 CAS 2017年第9期34-35,38,共3页 HUADIAN TECHNOLOGY
关键词 直接空冷系统 风机 变频器群 散热 水冷系统 direct air cooling system fan frequency converter group heat dissipation water cooling system
  • 相关文献

参考文献5

二级参考文献14

  • 1张舟云,徐国卿,沈祥林.牵引逆变器散热系统的分析与设计[J].同济大学学报(自然科学版),2004,32(6):775-778. 被引量:32
  • 2[5]Wang Dan,Mao Chengxiong,Lu Jiming,et aL.Design of Snubber for Series IGCTs Used in High Power and Medium Voltage Converter[A].38th International Universities Power Engineering Conference (UPCE)[C]2003:157~160.
  • 3中华人民共和国国务院.国家中长期科学和技术发展规划纲要(2006-2020)[R].北京:中华人民共和国国务院,2006.
  • 4国核电力规划设计研究院.空冷设计方案研究专题报告[R].2010.
  • 5孔邵文,乔栋.空冷机组煤耗高和节水效益分析[R].中国电机工程学会火电分会空冷技术专委会汽轮机学术会议.2001.
  • 6陈立平.灵武电厂二期工程空冷机组技术方案及经济性分析[R].2009.
  • 7Wang Dan,Mao Chengxiong,Lu Jiming,et al.Design of Snubber for Series IGCTsUsed in High Power and Medium Voltage Converter [A].38th International Universities Power Engineering Conference (UPEC)[C].2003:157~160.
  • 8韩安荣.通用变频器及其应用(第2版)[M].北京:机械工业出版社,2002..
  • 9ACS1000变频器硬件手册[S].
  • 10ACSl000变频嚣故障手册[S].