摘要 目的 探讨两种原理两种规则白细胞分类复检率的差异.方法 随机收集体检者100例,分别用染色法和VCS法同时检测白细胞分类参数,在4 小时内检测完毕.结果 用本实验室复检规则时,其中淋巴细胞(〉 4 0%)时两种原理检测的结果P〈0. 01.中性粒细胞(〈50%)时两种比较有意义, P〈0. 05.用浙江省复检规则时,中性粒细胞(〈 5 5 % )时,两种比较有差异, P〈0.05.中性粒细胞绝对值(小于3.0,大于5.8*109/L)时,两种原理有差异( P〈 0 . 05).结 论 淋 巴细胞(〉 4 0 % )、中性粒细胞(〈50%,〈55%)以及中性粒细胞绝对值(小于3.0,大于5. 8X 109/L)时,使用两种原理及两种复检规则时有差异.其它细胞分类在复检规则下没有差异.表明用不同原理仪器进行白细胞分类时要建立不同原理、不同仪器白细胞分类复检规则,这样才能保证分类的准确,提高工作效率. Objective To investigate the difference between the two principles of White blood cell classification review. Methods 100 cases were randomly collected from volunteers, respectively by staining and VCS for simultaneous detection of white blood cell classification parameters, completed in 4 hours. Results LAB review rules, in which Lymphocytes is greater than 40% two principles of detection results, there was a statiscally significant (P〈C0. 01). PMN is less than 50%two of the more meaningful (P 〈0. 01). eview rules of Zhejiang Province,PMN is less than 55%two of the more varied (P〈C0. 05). Neutrophil absolute value is less than 3. 0X 109/L when greater than 5. 8X 109/L , two principles are different (_ P〈0. 01). Conclusion Lymphocyte percentage 040 %),PMN percentage(〈50% and〈55%) ,Neutrophil absolute value (〈3. 0X 109/L and〉5. 8 X 109/L ) , two principle using the re-inspection rules there are difference, other cell did not. Differ between classification. . It shows that different instruments of the principle of white blood cell fraction,to create different principle instrument leucocyte fraction review rules. So as to ensure cor-rectness rate , improve the wore efficiency.
出处 《国际检验医学杂志》 CAS 2014年第A02期7-8,共2页 International Journal of Laboratory Medicine
关键词 两种原理 两种复检规则 白细胞分类 差异 Two principle Two kind of review criteria White blood cell classification Difference
  • 相关文献

参考文献12

二级参考文献37

共引文献121

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部