论文研究了悬浮物测定中因滤膜所含水溶物性物质而造成的负误差影响。对滤膜使用浸泡—抽滤的方法进行预处理,可有效解决较清洁水样悬浮物测定的负值现象,准确地反映了水样中悬浮物的实际浓度。
This paper studies negative error impact caused by water soluble property in membrane in the determination of suspended solids. Using the method of soaking-suction filter to preprocess membrane filter, which can effectively solve the negative phenomenon in clean water samples determination of suspended solids, accurately reflect the actual concentration of suspended solids in water samples.
作者
林文伟
陈鸿源
LIN Wen-wei CHEN Hong-yuan(Environmental Monitoring Station ofShishi, Shishi 362700, Chin)
出处
《中小企业管理与科技》
2017年第29期170-172,共3页
Management & Technology of SME
关键词
悬浮物
负误差
前处理
suspended solids
negative error
pretreatment