期刊文献+

基于过滤浓度日数的新风PM2.5过滤负荷特性研究 被引量:2

Filtering Load of Outdoor PM2.5 for Buildings Based on Concept of Filtering Concentration Days
下载PDF
导出
摘要 我国建筑环境PM2.5过滤或净化计算方法研究已引起广泛关注.针对我国不同区域新风PM2.5过滤负荷差异及变迁,引入不保证天数法,计算确定了各地区PM2.5新风设计负荷;类比空调度日数和采暖度日数提出过滤浓度日数FCD的概念;根据各地PM2.5动态浓度数据及其室内标准浓度,计算得到了历年全国省会及直辖市的FCD;利用统计学方法获得了各地区FCD和新风设计负荷的关系.研究结果表明,FCD指标清晰地反映了全国各地新风PM2.5设计计算负荷水平;FCD值与新风设计负荷表现为高度线性相关,显著性水平P<0.01;可用FCD来直接指示建筑PM2.5的新风设计负荷水平,可为将来新风PM2.5过滤系统设计、对比提供简单直观的依据. Filtering loads of outdoor PM2.5 for all province capital of China are determined with the method of unguarantee days. The concept of filtering concentration days (FCD) is proposed with the analogy of the cooling degree days (CDD) and heating degroo days (HI)D). Based on PM2.5 concentrations dynamic data and the base concentration, the FCDs of all province capital are calculated. The relationship between FCD and the filtering load of outdoor PM2. 5 is analyzed with a statistical way. The result shows: FCD is highly linear correlated with the filtering load of outdoor PM2.5 with P〈0.01. And FCD can be used as the climatic indicator of the demand for filtering services. Besides, it can provide a straightforward basis for the filtering system design.
作者 张承全 高军 曾令杰 叶蔚 ZHANG Chengquan GAO Jun ZENG Lingjie YE Wei(College of Mechanical Engineering, Tongji University, Shanghai 200092, Chin)
出处 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2017年第9期1345-1351,共7页 Journal of Tongji University:Natural Science
基金 中央高校基本科研业务经费专项资金(1000219177)
关键词 PM2.5 过滤浓度日数 新风过滤 过滤负荷 保证天数 PM2.5 filtering concentration days filtering ofoutdoor air filtering load unguarantee days
  • 相关文献

参考文献13

二级参考文献178

共引文献231

同被引文献16

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部