目的研究原水初始pH值、不同NaCl质量浓度和水力停留时间(HRT)对连续流双室微生物燃料电池的产电及污水处理效果的影响,使其产电及污水处理效果可以达到最好.方法试验以生活污水为研究对象,自行设计连续流双室微生物燃料电池处理工艺装置进行试验.结果在原水初始pH值为8、NaCl质量浓度为5 g/L和HRT为24 h时,连续流双室微生物燃料电池产电及污水处理效果可以达到最好.结论原水初始pH值、原水不同NaCl质量浓度和水力停留时间(HRT)对微生物燃料电池产电及污水处理效果的影响均较大.
The paper studied the effect of initial pH value,different concentrations of NaCl and HRT of raw water on the electricity production and sewage treatment to find the best experimental conditions. Sewage was treated as research object and continuous cycle double-microbial fuel cell treatment process device was designed by self to study. When the initial pH value was 8, the concentrations of NaCl was 5 g/L and HRT was 24 h of raw water,electricity production and sewage treatment of the MFC could be best. The initial pH value,different concentrations of NaCl and HRT of raw water had great influence on the electricity production and sewage treatment.