摘要 通过对某110 k V变电站21C电容器组故障跳闸的检查试验、故障录波分析以及EMTP/ATP仿真计算,找出造成该电容器故障的原因主要有:一是B5电容器在合闸前便存在绝缘薄弱的缺陷,一经合闸发生绝缘击穿;二是B5电容器的熔断器在合闸前存在接触不良缺陷,一经合闸熔断器内部发生间隙放电,受高频放电电流的作用B5电容器发生击穿。引入EMTP/ATP仿真计算为电容器类似故障原因分析提供新的方法,积累经验,具有一定的工程实际意义。 The fault reason of capacitor is found through the inspection and test of the tripping, fault record wave analysis and EMTP/ATP simulation calculation of 21C capacitor bank of certain a 110 kV substation as follows:The first reason is that B5 capacitor has the defect of weak insulation before closing operation and, in case of closing operation, the insulation breakdown occurs; the second one is that the fuse of B5 capacitor has the defect of weak contact before closing operation and, in case of closing operation, the gap discharges occurs inside the fuse and therefore the B5 capacitor occurs breakdown due to the action of high frequency discharge current.The EMTP/ATP simulation calculation is introduced so to provide new method for the analysis of the similar fault of capacitor, accumulate experience, which has a definite engineering practical significance.
出处 《电力电容器与无功补偿》 北大核心 2017年第5期17-21,共5页 Power Capacitor & Reactive Power Compensation
关键词 电容器组 故障跳闸 原因分析 EMTP/ATP capacitor bank fault trip reason analysis EMTP/ATP
  • 相关文献

参考文献11

二级参考文献56

  • 1倪学锋,盛国钊,林浩.我国电力电容器的运行与改进建议[J].电力设备,2004,5(9):10-13. 被引量:32
  • 2沈文琪.温度、电压、谐波、涌流等对电容器寿命的影响[J].电力电容器,2005(2):6-8. 被引量:50
  • 3张星海,张血琴,吴广宁.无功补偿电容器绝缘保护技术的研究[J].高电压技术,2005,31(12):18-20. 被引量:9
  • 4西北电力设计院.电气工程设计手册[M].北京:水利电力出版社,1990..
  • 5RAMASAMYNATARAJAN.电力电容器[M].徐政,译.北京:机械工业出版社.2007.
  • 6MARTIN BISHOP,TIM DAY,ARVIND CHAUDHARY.A Primer on Capacitor Bank Protection[J].IEEE Trans. on Industry Applications,2001,37(4) :1 174-1 179.
  • 7CYGAN P AND,LAGHARI J R.Models for Insulation Aging under Electrical and Thermal Multistress [J].IEEE Trans. Dielectrics Electrical Insulation, 1990,25(5) :923-934.
  • 8GREBE T E,GUNTHER E W.Application of the EMTP for Analysis of Utility Capacitor Switching Mitigation Techniques [C]//the 8th ICHQP'98,1998:583-589.
  • 9Working Group3.4.17 of IEEE. Impact of Shunt Capacitor Banks on Substation Surge Environment and Surge Arrester Applications[J].IEEE Trans. on Power Delivery, 1996,11 (4) : 1 798-1 806.
  • 10MICHAEL L GASPERI.Life Prediction Modeling of Bus Capacitors in AC Variable Frequency Drives [J].IEEE Trans. on Industry Applications,2005,41 (6) : 1 430-1 435.

共引文献138

同被引文献9

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部