期刊文献+

一起“三合一”场所较大亡人火灾事故调查与分析 被引量:6

Investigation and analysis of a large fire accident in a "three in one" place
下载PDF
导出
摘要 通过对一起"三合一"场所较大亡人火灾事故进行调查分析,充分应用火灾现场遗留的火势蔓延痕迹,精确认定起火部位及起火点。根据物证鉴定结果,最终认定火灾原因为电冰箱电气线路发生故障引起。探讨此类火灾现场痕迹发现与应用及灾害成因,如建筑消防设计不规范、管理混乱、人员消防意识差等。从应用多种现场痕迹、火场环境勘查技术等方面总结火灾调查体会。 Through investigation on a large fire accident in a "three in one" place, fully used on-site fire spread trace, and the fire origin and fire point was accurately determined. According to the material evidence identification results, the fire cause was finally identified as electrical line failure of refrigerator. Discussed discovery of on-site trace and its application and disaster cause including illegal fire safety design, confusion in management and poor consciousness of personnel. The fire investigation experience was concluded from various on-site trace and fire field exploration techniques.
作者 马涛
机构地区 四川省消防总队
出处 《消防科学与技术》 CAS 北大核心 2017年第9期1318-1321,共4页 Fire Science and Technology
关键词 “三合一”场所 火灾 火灾调查 现场痕迹 "three in one" place fire fire investigation on-site trace
  • 相关文献

参考文献3

二级参考文献18

共引文献26

同被引文献17

引证文献6

二级引证文献18

相关作者