分析了机组正常运行期间电力系统稳定器(PSS)出现频繁投退以及长时间退出的原因,结合PSS功率自动投退的实现逻辑及影响燃煤机组运行工况的3方面因素,提出一种适合于燃煤机组PSS功率自动投退定值的整定方法。以某1 000 MW燃煤机组为例,优化整定了该机组的PSS功率投退定值,优化后的PSS能消除频繁投退及长时间退出现象。该方法简单实用,适合工程化应用。
This paper analyses the causes of the power system stabilizer (PSS) frequent act and return as well as long-term offline during the normal operation of the coal-fired units. Taking the logic of PSS power automatic action and return and the three factors affecting the operating condition of the coal-fired units into account, the paper proposes a method of setting value tuning that is suitable for coal-fired units' PSS power automatic action anti return. By using this method, the PSS action and return setting values of a 1 000 MW coal-fired unit are optimized. The optimization is able to eliminate the PSS frequent act and return and long-term offline. The result shows that the method is easy to practice and applicable in the industry.
出处
《中国电力》
CSCD
北大核心
2017年第10期124-128,共5页
Electric Power
基金
国网浙江省电力公司科技项目(5211DS150025)~~
关键词
燃煤机组
电力系统稳定器
投入定值
退出定值
参数整定
coal-fired unit
power system stabilizer (PSS)
action value
return value
tuning method