期刊文献+

锥束X线发光断层成像/CT同步成像控制系统实现 被引量:4

Synchronous imaging control system for two modes of cone beam X-ray luminescence CT and CT
下载PDF
导出
摘要 目的:设计并实现锥束X线激发光学断层成像(cone beam X-ray luminescence CT,CB-XLCT)/CT双模同步成像控制系统,为CB-XLCT小动物活体成像研究提供软件控制平台。方法:基于实验室现有的CB-XLCT/CT系统,利用Microsoft Visual Studio 2010平台,使用多线程编程技术和动态链接库,搭建软件控制平台,实现双模数据的同步采集。通过设计仿体实验,联合CT稀疏角度重建算法,对系统成像性能进行评价。结果:仿体实验结果表明该系统同步成像控制比非同步成像采集时间缩短79%,且成像质量完全可以满足实际需求。结论:CB-XLCT/CT同步成像控制系统有利于CB-XLCT在体研究的开展。 Objective To design and implement a synchronous imaging control system for two modes of cone beam X-ray luminescence CT(CB-XLCT) and CT to provide a software control platform for small animal in vivo imaging. Methods The software control platform was developed with the existing CB-XLCT/CT system, Microsoft Visual Studio 2010 platform, multi thread programming technology and dynamic link library so as to realize synchronous acquisition of two-mode data. The performances of the system imaging were evaluated by designing phantom experiments combined with sparse-view CT reconstruction algorithm. Results The phantom experiments results showed that synchronous imaging control had the acquisition time decreased by 79% when compared with non-synchronous imaging, and the requirements were met for imaging quality. Conclusion Synchronous imaging control of CB-XLCT/CT facilitates in vivo researches for small animals.
出处 《医疗卫生装备》 CAS 2017年第9期1-4,11,共5页 Chinese Medical Equipment Journal
基金 国家自然科学基金资助项目(81230035) 陕西省自然科学基金资助项目(2016JQ1012)
关键词 X线发光断层成像 CT 同步采集 多线程 X-ray luminescence CT CT synchronous acquisition multi thread
  • 相关文献

参考文献7

二级参考文献29

  • 1胡小春,郭松青,叶铭.基于CT图像建立人体足部骨骼三维有限元模型的研究[J].合肥工业大学学报(自然科学版),2005,28(9):1188-1191. 被引量:28
  • 2孙丰荣,刘泽,李艳玲,曲怀敬,张梅,张运.基于模型的CT三维医学图像重建仿真[J].系统仿真学报,2006,18(3):781-784. 被引量:14
  • 3郑诚功,黄昌弘,魏鸿文,张宗维.膝关节的生物力学性能简介(上)[J].中华骨科杂志,2006,26(12):862-864. 被引量:14
  • 4[4]启明丁作室.Visual C+++SQL Server数据库应用系统开发与实例.北京:人民邮电出版社,2004
  • 5HSIEH J.Computed tomography:principles,design,artifacts,and recent advances[M].Bellingham:SPIE,2002.
  • 6ZHU Shou-ping,TIAN Jie,YAN Guo-rui,et al.Cone beam micro-CT system for small animal imaging and performance evaluation[J].Int J Biomed Imaging,2009,2009:960573-960579.
  • 7ZHU Shou-ping,TIAN Jie,YAN Guo-rui.An experimental cone-beam micro-CT system for small animal imaging[C].SPIE,2009,7258:72582S.
  • 8SMITH B D.Image reconstruction from conebeam projections:necessary and sufficient conditions and reconstruction methods[J].IEEE Trans Med Imaging,1985,MI-4(1):4-25.
  • 9KAK A C,SLANEY M.Principles of computerized tomographic imaging[M].New York:IEEE,1988.
  • 10CHEN Zi-kuan,CALHOUN V D,CHANG Sheng-jiang.Compensating the intensity fall-off effect in cone-beam tomography by an empirical weight formula[J].Appl Opt,2008,47(32):6033-6039.