期刊文献+

浓水流量对电渗析脱盐过程性能参数的影响

Impact of Concentrated Water Flow Rate on Performance Parameters of Electrodialysis Desalination Process
下载PDF
导出
摘要 采用电渗析装置,对苦咸水脱盐过程进行了研究。考察了浓水流量、操作电压对膜堆电流、电阻、脱盐率、系统能耗的影响。结果表明,提高浓水流量与加大操作电压均使电渗析的传质通量(脱盐率)和操作电流提高,系统能耗增大。膜堆电阻变化较为复杂,操作电压<20V时,膜堆电阻降低;操作电压为20~30V时,膜堆电阻基本保持不变;操作电压>30V时,膜堆电阻增大。 Electrodialysis devices are used for studying the process of brackish water desalination. Influence of concentrated water flow and operating voltage on current of membrane reactor, resistance of the membrane,desalination rate and energy consumption of the system are researched. The results show that improving the concentrated water flow and operating voltage can both make the mass transfer flux of electrodialysis device increase, at the same time, operating current and the system energy consumption also increase. With the changes of operating voltage,the change of resistance of the membrane is relatively complex. When operating voltage is less than 20 V,resistance of the membrane decreases. Resistance of the membrane basically remains unchanged when operating voltage is between 20 ?30 V,while increases when operating voltage is higher than 30 V.
出处 《净水技术》 CAS 2017年第10期75-79,共5页 Water Purification Technology
基金 海洋公益性行业科研专项经费项目(201405035) 中央级公益性科研院所基本科研业务费专项资金项目(K-JBYWF-2015-G01) 中央级公益性科研院所基本科研业务费专项资金项目(K-JBYWF-2016-G03) 中央级公益性科研院所基本科研业务费专项资金项目(K-JBYWF-2015-T03)
关键词 电渗析 水流量 操作电压 性能参数 electrodialysis( ED) concentrated water flow rate electric-current density desalination rate energy consumption
  • 相关文献

参考文献1

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部