通过曝气生物滤池(BAF)+絮凝沉淀+超滤(UF)组合工艺各单元对源城污水处理厂尾水污染物的去除分析,从设计参数选择、设备选型、运营期数据验证等方面,论证了组合工艺在源城污水处理厂尾水提标至地表Ⅲ类水工程上的可行性与可靠性。
By using the each unit of the combined process-BAF + flocculent serrling + UF,to analyse the tail water pollutant removing of Yuancheng sewage treatment plant. Referring to design parameters selection,equipment selection,operation data validation,this essay argues the feasibility and reliability of improving it's criterion of tail water to class Ⅲ criteria of surface water engineering.