期刊文献+

尿液细胞外囊泡检测及其临床应用进展 被引量:1

Urine extracelluar vesicle determination and its research progress
下载PDF
导出
摘要 细胞外囊泡(EV)是机体内细胞在向外出芽和细胞膜裂变过程中释放出的微小囊泡,内含特异性生物活性分子,如蛋白质、核酸和脂质,因此有望成为临床疾病新型标志物。EV广泛存在于人类的各种体液中,其中尿液是研究EV的良好对象,具有标本量充足、标本易得且无创等特点。尿液EV内容物是潜在的疾病标志物。文章对尿液EV的检测方法及其临床应用作了综述。 Extracelluar vesicles(EV) are vesicles which are released from most cell types during budding and cell membrane fission. EV specific molecules,such as proteins,nucleic acids and lipids,are expected as novel biomarkers. EV exists in the body uid of human body. Urine is a good target for the research of EV,with the advantages of sufficient volume,obtaining easily and non-invasive operation. The component urine EV may be potential as biomarkers of various diseases. This review mainly focuses on the determination of urine EV and its clinical application.
作者 徐咏 郑磊
出处 《检验医学》 CAS 2017年第10期102-109,共8页 Laboratory Medicine
基金 国家自然科学基金项目(81371901) 广州市科技计划项目(201510010097) 广州健康医疗协同创新重大专项(201604020015)
关键词 细胞外囊泡 尿液 新型标志物 Extracelluar vesicle Urine Novel biomarker
  • 相关文献

参考文献3

二级参考文献67

  • 1Yuille M, Illig T, Hveem K. Laboratory management of samples in biobanks: European consensus expert group report [J]. Biopreserv Biobank, 2010, 8(1) : 65 -69.
  • 2Spierto FW, Hannon WH, Gunter EW, et al. Stabili- ty of urine creatinine[ J]. Clin China Acta, 1997, 264 (2) : 227-232.
  • 3Miki K, Sudo A. Effect of urine pH, storage time, and temperature on stability of catecholamines, corti- sol, and creatinine[J]. Clin Chem, 1998, 44(8 Pt 1) : 1759-1762.
  • 4Collins AC, Sethi M, MacDonald FA, et al. Storage temperature and differing methods of sample prepara- tion in the measurement of urinary albumin [ J ]. Dia- betologia, 1993, 36(10) : 993-997.
  • 5Grubb A. Diagnostic value of analysis of cystatin C and protein HC in biological fluids [ J ]. Clin Nephrol, 1992, 38(Suppl 1) : $20-$27.
  • 6Uchida K, Gotoh A. Measurement of cystatin-C and creatinine in urine [ J]. Clin Chim Acta, 2002, 323 (1-2) : 121-128.
  • 7Finney H, Newman D J, Gruber W, et al. Initial evaluation of cystatin C measurement by particle- enhanced immunonephelometry on the Behring nephe- lometer systems (BNA, BN II ) [J]. Clin Chem, 1997, 43(6 Pt 1) : 1016-1022.
  • 8Mussap M, Ruzzante N, Varagnolo M, et al. Quanti- tative automated particle-enhanced immunonephelo- metric assay for the routinary measurement of human cystatin C[J]. Clin Chem Lab Med, 1998, 36(11): 859-865.
  • 9Herget-Rosenthal S, Feldkamp T, Volbracht L, et al. Measurement of urinary cystatin C by particle- enhanced nephelometric immunoassay : precision, in- terferences, stability and reference range [ J ]. Ann Clin Biochem, 2004, 41(Pt 2) : 111-118.
  • 10Han WK, Wagener G, Zhu Y, et al. Urinary biomar-kers in the early detection of acute kidney injury after cardiac surgery[J]. Clin J Am Soc Nephrol, 2009, 4 ( 5 ) : 873-882.

共引文献14