对比不同CT扫描方式的辐射剂量与图像质量 被引量:5

下载PDF
导出
摘要 目的:对比评价常规CT扫描与胸部能谱成像应用于临床检查时的射线辐射剂量与图像质量。方法:将医院2017年1月~4月收治因病情需要行胸部CT检查的52例患者作为研究对象,患者均行常规CT平扫与胸部能谱成像扫描,并对两种CT扫描方式的辐射剂量与图像质量进行比较,以评价最佳扫描方式。结果:不同CT扫描方式比较可见,常规CT平扫与能谱动脉期成像的辐射剂量及图像质量相当(P>0.05);而能谱静脉期成像虽然比常规CT平扫有较高辐射剂量,但所提供的图像质量也更佳(P<0.05)。结论:与120k Vp常规CT平扫相比,胸部动脉期能谱成像的辐射剂相当,胸部静脉期能谱成像虽然有较高辐射剂量,但所获得的图像质量,可在临床酌情考虑应用。
作者 景建超
出处 《现代医用影像学》 2017年第4期1008-1009,共2页 Modern Medical Imageology
  • 相关文献

参考文献2

二级参考文献21

  • 1Hsiao EM,Rybicki FJ,Steigner M. CT coronary angiography:256-slice and 320-detector row scanners[J]. Curr Cardiol Rep, 2010, 12(1) : 68-75.
  • 2Choi SI,George RT,Schuleri KH,et al.Recent developments in wide-detector cardiac computed tomography[J].Int J Cardiovasc Imaging, 2009,25(Suppl 1): 23-29.
  • 3Perisinakis K,Papadakis AE,Damilakis J.The effect of X-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging[J]. Med Phys, 2009,36(4).. 1258- 1266.
  • 4Fuchs TA,Stehli J,Fiechter M,et al. First experience with monochromatic coronary computed tomography angiography from a 64-slice CT scanner with Gemstone Spectral Imaging(GSI)[J].J Cardiovasc Comput Tomogr, 2013,7(1): 25-31.
  • 5Deng K,Zhang CQ,Li W,et al.Preliminary application of high-definition CT Gemstone Spectral Imaging in hand and foot tendons[J]. Korean J Radiol, 2012,13(6): 743-751.
  • 6Wang L,Liu B,Wu XW,et al. Correlation between CT attenuation value and iodine concentration in vitro:discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging[J].J Med Imaging Radiat Oncol,2012,56(4). 379-383.
  • 7Lee YH,Park KK,Song HT,et al.Metal artefact reduction in gemstone sptml imaging dual-energy CT with and without metal artefact reduction software[J]. Eur Radiol, 2012,22(6): 1331- 1340.
  • 8Zhang D,Li X,Liu B.Objective characterization of GE discovery CT750 HD scanner.gemstone spectral imaging mode[J].Med Phys,2011,38(3): 1178- 1188.
  • 9Lin XZ,Miao F,Li JY,et al.High-definition CT Gemstone spectral imaging of the brain:initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction[J].J Comput Assist Tomogr, 2011,35(2).. 294-297.
  • 10Mieville FA,Gudinchet F,Brunelle F,et al. Iterative reconstruction methods in two different MDCT scanners.Physical metrics and 4-alternative forced-choice detectability experiments-A phantom approach[J].Phys Med, 2013,29(1): 99-110.