期刊文献+

燃用劣质褐煤的600 MW超临界循环流化床锅炉煤仓间布置设计优化 被引量:1

Inferior-lignite-fired 600 MW supercritical circulating fluidized bed boiler bunker bay arrangement design improvement
下载PDF
导出
摘要 以燃用劣质褐煤(高水分、超低热值)的循环流化床锅炉煤仓间为研究对象,为提高锅炉给煤的可靠性、均匀性和可控性,对煤仓间的布置进行设计优化,提出了内嵌于锅炉双侧的煤仓间布置方案,在技术、经济效益方面具有显著优势。 Based on a circulating fluidized bed boiler which burning inferior lignite,to increase reliability,uniformity and controllability of boiler coal feeding,the arrangement of coal bunker bay was improved. The alignment of to embed bunker bay beside boiler was introduced. This arrangement take remarkable advantage on technical and economic aspect.
出处 《华电技术》 CAS 2017年第10期30-31,40,共3页 HUADIAN TECHNOLOGY
关键词 循环流化床锅炉 劣质褐煤 煤仓间 布置 设计优化 circulating fluidized bed boiler inferior lignite bunker bay arrangement design improvement
  • 相关文献

参考文献4

二级参考文献11

  • 1苏阳,范洁.火电厂主厂房结构优化分析[J].河北电力技术,2007,26(6):47-49. 被引量:4
  • 2修瑞科.火电厂施工大型起重机械配备及布置[J].电力建设,2007,28(6):54-57. 被引量:6
  • 3DL5000-2000火电发电厂设计技术规程[S].北京:中国电力出版社.2001.
  • 4DL5000-2000,火力发电厂设计规程[S].
  • 5DL5009.1-1992电力建设安全工作规程(火力发电厂部分)[S].
  • 6DL5094-1999火力发电厂建筑设计规程[S].
  • 7DL5022-1993火力发电厂土建结构设计技术规定[S].
  • 8DLGJ99-1991火力发电厂主厂房:钢-混凝土组合结构设计暂行规定[S].
  • 9DL5032-2005火力发电厂总图运输设计技术规程[S].
  • 10DL5009.1-2002电力建设安全工作规程:第1部分火力发电厂[S].