摘要 Hamamatsu R1924A is one of the most widely used photomultiplier tubes(PMTs) in nuclear physics.Since the active base suitable for R1924A is still not available in market, an active base is designed for Hamamatsu R1924A PMT, and the test results at high counting rates are presented. The active bases with two different sets of resistor chains were tested and compared by a frequency-controlled green straw hat LED light. A stable signal output up to 100 kHz is achieved using frequency-controlled LED pulsed light. The temperature of bases, which reflects the power consumption and is crucial for applications in vacuum, is also monitored with the same LED pulsed light. The temperature of the active base with smaller resistances reaches about twice of that of the active base with larger resistances in the resistor chain. For the applications in vacuum, the active base with resistance between the two sets of resistor chains may be preferable. Hamamatsu R1924A is one of the most widely used photomultiplier tubes (PMTs) in nuclear physics. Since the active base suitable for R1924A is still not available in market, an active base is designed for Hamamatsu R1924A PMT, and the test results at high counting rates are presented. The active bases with two different sets of resistor chains were tested and compared by a fre- quency-controlled green straw hat LED light. A stable signal output up to 100 kHz is achieved usingfrequency-controlled LED pulsed light. The temperature of bases, which reflects the power consumption and is crucial for applications in vacuum, is also monitored with the same LED pulsed light. The temperature of the active base with smaller resistances reaches about twice of that of the active base with larger resistances in the resistor chain. For the applications in vacuum, the active base with resistance between the two sets of resistor chains may be preferable.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第10期59-63,共5页 核技术(英文)
基金 supported by the National Natural Science Foundation of China(Nos.91426301 and 11075189) the Strategic Priority Research Program of the Chinese Academy of Sciences"ADS project"(No.XDA03030200) the Program for the CAS"Light of West China"(No.29Y601030) the US Department of Energy(No.DE-FG02-93ER40773) the program of the"visiting professorship of senior international scientists of the Chinese Academy of Sciences"for their support during his stay at the IMP
关键词 光电倍增管 高计数率 应用 设计 活性基团 LED灯 频率控制 Active base High counting rate HamamatsuR1924A photomultiplier tube
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部