期刊文献+

地源热泵结合温湿度独立控制在办公建筑应用

Application of Ground Source Heat Pump Combined with Independent Control of Temperature and Humidity in an Office Building
下载PDF
导出
摘要 本文介绍了遵义卷烟厂办公建筑的空调设计方案,设计采用温湿度独立控制的理念,冷热源由高温型土壤源热泵机组提供。办公室等房间均采用预冷式溶液调湿新风机组完成对新风的处理,并承担室内湿负荷,干式风机盘管承担室内显热负荷。大型会议室等采用预冷式溶液调湿全空气处理机组来处理空气。 This paper describes the design of the air conditioning system of an office building in Zunyi Cigarette Factory. The design uses the concept of independent control of temperature and humidity. Hot or cold water of the air conditioning system is provided by high-temperature ground source heat pump. Pre-cooling type liquid desiccant fresh air units are used to complete the processing of fresh air. The fresh air undertakes indoor wet load. Dry fan coils undertake the indoor sensible heat load. Large eonference rooms use the pre-cooling type liquid desiccant air handing units to process the air.
作者 王冠军 王雷岗 李春强 WANG Guan-jun WANG Lei-gang LI Chun-qiang(SIPPR Engineering Group Co., Ltd. Zunyi Cigarette Factory of Guizhou Tobacco Corporation)
出处 《建筑热能通风空调》 2017年第10期42-44,共3页 Building Energy & Environment
关键词 温湿度独立控制 地源热泵 溶液调湿空调 干式风机盘管 temperature and humidity independent control, ground source heat pump, liquid desiccant air conditioning, dry fan coil