介绍了冷却塔供冷系统在上海保利凯悦酒店及商业文化中心酒店项目中的应用,对冷却塔供冷系统的设计方法进行了总结,阐述了系统设计中冷冻水、冷却水供回水温度的确定、水泵匹配、冷却塔配置、系统节能计算等问题。
The application of tower cooling system on Shanghai Poly Hyatt Hotel and Commerce-culture Center was introduced, and the design method of tower cooling system was summarized, and a series of points such as ascertainment of the supply and return water temperature, water pump matching, cooling tower configuration and system energy saving calculation, was pointed out.