1[1]Yiannikas C, Shahani BT. The origins of lumbosacral spinal evoked potentials in humans using a surface electrode recording technique. J Neurol Neurosurg Psychiatry, 1988,51:499 ~ 508.
2[2]Yamada T. Neuroanatomic substrates of lower extremity somatosensory evoked potentials. J Clin Neurophysiol,2000,17:269 ~ 279.
3[3]Lehmkuhl D, Dimitrijevic MR, Renouf F. Electrophysiological characteristics of lumboscral evoked potentials in patients with established spinal cord injury. Electroencephalogr Clin Neurophysiol, 1984,59:142~ 155.
4[4]HalonenJP,Jones SJ,EdgarMA,et al. Mult-level epidural recordings of spinal SEPs during scoliosis surgery. Electroeneephalogr Clin Neurophysiol, 1990,41 (suppl) :342 ~ 347.
5[5]Desmeddt JE, Cheron G. Spinal and far-field components of human somatosensory evoked potentials to posterior tibial nerve stinulation analysed with oesophageal derivations and non-cephalic reference reording. Electroencephalogr Clin Neurophysiol,1983,56:634 ~ 651.
6[6]Jeanmonod D,Sindon M,Maguiere F.Three transversedipolar generators in the humam cervical and lumbo-sacral dorsal horn:evidence from direct intraoperative recordings on the spinal cord surface. Electroencephalugr Clin Neurophysiol, 1989,74:236 ~ 240.
7[7]Lee EK, Seyal M. Generators of short latency human somatosensoryevoked potentials recorded over the spine and scalp. J Clin Neurophysiol, 1998,15:227 ~ 234.
8[8]Tinazzi M, Mauguiere F. Assessment of intraspinal and intracranial conductien by P30 and P39 tibial nerve somatosensory evoked potentials in cervical cord, brainstem, end hemispheric lesions. J Clin Neurophysiol,1995,12:237 ~ 253.
9[9]Buettner UW,Timmann D. Diagnostic significance of tibial nerve somatosensory evoked potentials with spinal cord lesions. Electroencephalogr Clin Neurophysiol(suppl), 1990,41:309 ~ 313.
10[10]Moller AR, Sekiya T, Sen CN. Responses fron dorsal colunn nuelei (DCN)in the monkey to stimulation of upper and lower limbs and spiral cord. Electroencephalogr Clin Neurophysiol, 1989,73:353 ~ 361.
5Branston NM, Bentivoglio P, Momma F, et al.Changes in pyramidal conduction with experimentai brainstem ischemia in the monkey[J]. Electroencephalogy Clin Neurophysiol, 1998, 69. 469-475.
7Lope.z. JR, Chang SD, Steinberg GK. The use of electrophysiological monitoring in the intraoperative management of intracranial aneurysms [J]. J Neurol Neurosurg Psychiatry, 1999, 66: 189-196.
8Duffau H, Lopes M, Arthuis F, et al. Contribution of intraoperative dectrical stimulations in surgery of low grade gliomas: a comparative study between two series without (1985- 96) and with (1996-2003) functional mapping in the same institution[J]. J Neurol Neurosurg Psychiatry, 2005, 76(6): 845-851.
9[kfffau H, Capelle L, Dmvil D, et aL Usefulness of intraoperative dectrical subcortical mapping during surgery for tow-grade glioroas located within dcquent brain regions: furmtional results in a consecutive series of 103 patients[J].J Neumsurg, 200a, 98(4) : 764-778.
10Luk KD, Hu Y, Wong YW, et al. Variability of somatosensory evoked potentials in different stages of seoliosis surgery [J]. Spine, 1999, 24: 1799-1804.