期刊文献+

一种多信息融合无创血糖检测数据处理方法研究 被引量:1

A research on data processing method for non-invasive blood glucose based on detection information fusion
下载PDF
导出
摘要 以生物特征检测技术为基础,基于已经构建的无创血糖检测系统进行血糖检测数据分析。以光电检测技术为主,结合其他人体特征信息检测,对人体进行无创血糖测试得到大量数据,建立数学模型并利用算法来计算血糖浓度。与一种常用有创血糖仪检测数据进行对比,有创与无创检测结果的相关系数达到了85.4%,为多信息融合无创血糖检测系统提供了一种有效的数据处理方法。 This paper takes the biometric detection technology as a foundation to analyze the data of blood sugar examination basing on the constructed no blood sugar detection system. Taking the photoelectric detection technology as the primary position,combined with other features of human body information detection,a large amount of data is obtained by the noninvasive testing to the human body. The mathematics model is set up to calculate the blood sugar concentration. Compared with a common information of the blood glucose meter traumatic inspection,the correlation coefficient of the test results for one tester achieves 0.854,which provides a kind of prospective data processing method for the systems of non invasive blood glucose detection with multi information fusion.
出处 《光学仪器》 2017年第5期1-7,共7页 Optical Instruments
基金 国家自然科学基金项目(61378035)
关键词 多信息融合 无创 血糖检测 multi information fusion non invasive blood glucose detection
  • 相关文献

参考文献4

二级参考文献57

  • 1陈文亮,徐可欣,杜振辉,刘蓉,范世福.人体无创血糖检测技术[J].仪器仪表学报,2003,24(z1):258-261. 被引量:18
  • 2马海涛,丁东,崔继承,唐玉国.近红外光谱在无创血糖监测中的应用[J].仪器仪表学报,2002,23(z3):231-233. 被引量:10
  • 3[1]D. Someya, Y. Nikawa M. Yamamoto. measurement of Blood Sugar Level Using Millimeter Waves. Korea-Japan Microwave Workshop(KJMW2000)Proceeding, Korea, 2000, 32~35.
  • 4[2]Y. Nikawa, D. Someya. Application of Millimeter Wave to Measure Blood Sugar Level. Proceeding of APMC2001, Taibei, Taiwan, 2001, 1303~1306.
  • 5[3]Cameron B D, Gorde H, Cote G L. Development of an optical polarimeter for in vivo glucose monitoring. Proceedings of SPIE, 1999,3599:43~49.
  • 6[4]Cameron B D, Cote G L. Polarimetric detection of chiral chemicals in biological fluids. Proceedings of SPIE, 1997,2982:308~313.
  • 7[5]Duncan Arlene, Hannigan John, Freeborn Scott S, et al.. Portable non-invasive blood glucose monitor. International Conference on Solid-State Sensors and Actuators, and Eurosensors IX,Proceedings 2,1995,455~458.
  • 8[6]Zhao Z M, Myllyla R. Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode. Proceedings of SPIE,2001,4256:77~83.
  • 9[7]Zhao Z M, Myllyl R. The effect of optical scattering on pulsed photoacoustic measurement in weakly absorbing liquid, Measurement Science and Technology,2001,12:2172~2177.
  • 10[8]Bednov A A, Karabutov A A, Savateeva E V, et al.. Monitoring glucose in vivo by measuring laser-induced acoustic profiles. Proceedings of SPIE,2000,3916:9~18.