生物质固定床气化炉异常工况的分析

Abnormal Operation Analyses of Biomass Fixed Bed Gasifier
下载PDF
导出
摘要 针对以空气为气化介质的径高比为0.32的下吸式固定床气化炉,当通风量为11 m3/h时,分别研究了在正常运行、"搭桥"及"烧穿"情况下反应温度及气化燃气组分百分率变化规律。研究结果表明,在发生"搭桥"、"烧穿"的异常工况下,反应温度会偏离正常值且各燃气组分百分率会明显下降,并分析了产生此效果的原因。 This paper mainly studied the varying patterns of the reaction temperature and gasification gas component percentage in the downdraft fixed-bed gasifier with 0. 32 diameter to height ratio and utilizing air as gasification agent under the normal operation,the 'bridging 'and 'burning through'cases when the ventilation rate is 11m3/h. The results showed that the reaction temperature would deviate from normal and each gas component percentage would decreased significantly in the abnormal cases of 'bridging 'and/or 'burning through'. At last,this paper analyzed the causes of this conclusion.
出处 《沈阳工程学院学报(自然科学版)》 2017年第2期131-134,共4页 Journal of Shenyang Institute of Engineering:Natural Science
关键词 生物质 下吸式固定床气化炉 反应温度 搭桥 烧穿 Biomass fuel Downdraft fixed-bed gasification furnace Reaction temperature Bridging Burning through