摘要
目的探讨称量法测定人血清密度的不确定度评定方法。方法应用称量法测定人血清密度,分析各不确定度分量的来源,并对各不确定度分量分别进行评定,计算合成标准不确定度和扩展不确定度。结果总蛋白(TP)为63.2 g/L的血清密度的合成标准不确定度为0.047 4 g/L,取包含因子(k)=1.96、95%置信区间,则扩展不确定度为0.093 g/L。结论应用称量法测定人血清密度建立的测量不确定度评定方法,可满足临床参考实验室对血清密度参考测量系统的要求。
Objective To evaluate the uncertainty in the determination of human serum density by weighing method.Methods The density of human serum was determined by weighing method,and all the sources of the uncertainty factors were analyzed. The uncertainties were evaluated separately,and the combined standard uncertainty and extended uncertainty were calculated. Results The standard uncertainty was 0. 047 4 g/L for serum with TP concentration of 63. 2 g/L,and the uncertainty was 0. 093 g/L with the inclusion factor( k) = 1. 96. Conclusion The method of measuring uncertainty in the measurement of human serum density by weighing method can meet the requirement of reference density measurement system in clinical laboratories.
出处
《中国卫生检验杂志》
CAS
2017年第20期2968-2970,共3页
Chinese Journal of Health Laboratory Technology
关键词
测量不确定度
血清密度
测量不确定度表示指南
Measurement uncertainty
Density of serum
Guide to the uncertainty in measurement