期刊文献+

全自动烷基汞分析仪测定水中烷基汞的方法研究 被引量:8

Research on Determination of Alkyl Mercury in Water by Automated Alkyl Mercury Analytical System
下载PDF
导出
摘要 建立了全自动烷基汞分析仪测定水中的烷基汞(甲基汞,乙基汞)的方法。实验中衍生化反应所用的试剂为含有2.0 mol/L醋酸缓冲液,1%(g/v)NaBEt4(四乙基硼化钠)和1%(g/v)NaBPr4(四丙基硼化钠)的2%(g/v)氢氧化钾-水溶液,经衍生化的水样直接吹扫捕集后,进入气相色谱柱中分离并高温裂解,最后进入冷原子荧光检测器(CVAFS)中检测甲基汞和乙基汞的含量。甲基汞和乙基汞的方法检出限分别为0.002 ng/L和0.005 ng/L。 A confirmatory method is presented for the determination of Alkyl Mercury( Methyl mercury,Ethyl mercury) in water samples by Automated Alkyl Mercury Analytical System. A 2%( g/v) potassium hydroxide-water mobile phase containing 0.2 mol/L acetic acid buffer,1%( g/v) NaBEt4( sodium ethyl boride) and 1%( g/v) NaBPr4( four propyl sodium boride) was used for derivatization reaction of Alkyl Mercury( methyl mercury,ethyl mercury) by automated alkyl mercury analytical system. The concentrations of two species in eluent were detected by CVAFS. The limits of the method were about 0. 07 pg and 0. 12 pg for methyl mercury,ethyl mercury respectively.
出处 《环境科学与管理》 CAS 2017年第4期113-115,共3页 Environmental Science and Management
关键词 全自动烷基汞分析仪 烷基汞 衍生化反应 automated alkyl mercury analyt ical system alkyl mercury derivatization reaction