期刊文献+

圆棒手动超声波探伤灵敏度调整及缺陷定量评定 被引量:4

Adjustment of the Flaw Detection Sensitivity and the Quantitative Evaluation of the Flaw of Manual Ultrasonic on Round Bars
下载PDF
导出
摘要 手动超声波探伤仪具有携带方便、使用灵活的特点,根据其探头型号2.5P12可计算出近场区长度,利用声压发射规律可计算出Φ12~Φ72 mm圆棒需使用对比试块法调整探伤灵敏度,Φ73~Φ310 mm圆棒可使用底波方式法调整探伤灵敏度。缺陷的定量评定采用当量计算法和对比试块法评定。 Manual ultrasonic flaw detector is easy to carry and flexible to use. According to the type of probe 2.5P12, the near field length of N=15.38 mm can be calculated. Using acoustic emission rules, it can be calculated to adjust the detection sensitivity for 12-72 mm diameter rods using contrast test block method. The bottom wave is used to adjust detection sensitivity for 73-320 mm diameter rods. The quantitative evaluation of delfts is calculated by the equivalent calculation method and the contrast test block method.
作者 李金浩
出处 《山东冶金》 CAS 2017年第5期47-49,共3页 Shandong Metallurgy
关键词 圆棒探伤 手动超声波探伤仪 灵敏度调整 缺陷评定 round bar flaw detection manual ultrasonic flaw detector sensitivity adjustment defect evaluation
  • 相关文献

参考文献1

同被引文献24

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部