期刊文献+

驱动控制器瓷介电容器烧毁故障分析

Failure Analysis of Ceramic Dielectric Capacitor Burning in Drive Controller
下载PDF
导出
摘要 针对在环境应力筛选中因滤波用军用片式多层瓷介电容器烧毁致使驱动控制器无输出的故障现象,从电应力、热应力、机械应力、电容器内在缺陷等方面深入分析,构建了故障树,确定了固定滤波电感的机械应力是造成故障出现的根本原因,克服了分析过程的常规思维定势。 For in environmental stress screening for filtering in military chip multilayer ceramic dielectric capa- citor burned led drive controller without output fault phenomena,from the respect such as electrical stress,th- ermal stress,mechanical stress,inherent defect analysis,has constructed the fault tree,determine the mechan- ical stress of fixed filter inductance is the root cause of failure occurs,overcome the conventional mindset of t- he analysis process.
作者 赵涛 胥春茜 Zhao Tao;Xu Chun-qian(The 16th Research Institute of China electronic technology group Corporation,AnHui Hefei 230043)
出处 《电子质量》 2017年第11期34-38,共5页 Electronics Quality
关键词 瓷介电容器 故障分析 技术归零 ceramic dielectric capacitor fault analysis technical problem close loop