期刊文献+

回转动力泵测量不确定度比对计算

Indeterminacy contradistinction calculation of rotary power pump
原文传递
导出
摘要 比对GB/T 3216回转动力泵水力性能验收试验标准2005版和2016版中测量不确定度计算条款,分析了标准对水泵测试系统不确定度要求的差异,阐述了水泵测试系统不确定度评定的计算过程。举例用EXCEL工具比对计算了水泵测试系统的不确定度,细化了水泵实验室不确定度评定计算,为进一步理解和贯彻实施标准将会起到积极作用。 This paper compared the calculation clauses of indeterminacy measuring in GB/T 3216-2005 with GB/T 3216-2016 which are the performances acceptance test standards of rotary power pump, and analyzed the difference between these two kinds of standards indeterminacy demands in the pump test system, also expounded the indeterminacy appraisal calculation progress in the pump test system. Excel also had been used to calculate the pump test system indeterminacy by giving an example. This paper made detailed in- determinacy appraisal calculations, and played an active part in further understanding and carrying out standard.
出处 《自动化与仪器仪表》 2017年第11期21-23,26,共4页 Automation & Instrumentation
关键词 回转动力泵 水泵测试系统 测量不确定度 评定 比对 rotary power pump pump test system indeterminacy measuring appraisal contradistinctions
  • 相关文献

参考文献9

二级参考文献50

  • 1张红飙.产品质量检测不确定度的分析及应用[J].中国测试技术,2005,31(3):65-67. 被引量:14
  • 2JJF1059-1999.《测量不确定度评定与表示》[S].[S].国家质量技术监督局,..
  • 3国家质量技术监督局.测量不确定度评定与表示,1999.
  • 4倪育才.实用测量不确定度评定,2007.
  • 5费业态.误差理论与数据处理,2002.
  • 6王辉,沈钺.相关性条件下合成不确定度的MC方法[J].电测与仪表,2007,44(10):37-39. 被引量:1
  • 7JJF1059.1-2012,测量不确定度评定与表示[S].北京:国家质量监督检验检疫总局,2011.
  • 8JJF1059. 1 - 2012.测量不确定度评定与表示[S].2013.
  • 9ISO/IEC 98-3,Uncertainty of measurement —Part 3 : theGuide to the expression of uncertainty in measurement[S].1999.
  • 10JJF1059.2 -2012.用蒙特卡罗法评定测量不确定度[S].2013.