摘要 Actiflo~ Turbo工艺是在原Actiflo~微砂加重絮凝高效沉淀工艺的基础上改进更新的,具有抗冲击负荷能力强、快速启动、SS去除率高、运行灵活、占地面积小等特点。介绍了工艺原理、核心设备、工艺特点和适用性。该工艺实际应用于法国里尔市Marquette-Lez-Lille污水厂大流量暴雨水处理,出水指标达到设计要求,可用于湿地灌溉。 The Actiflo Turbo process is an improved, compact, physical-chemical process basedon the original Actiflo micro-sand flocculation and sedimentation process, with the characteristics of highimpact load capacity, quick start-up, high removal efficiency of SS, flexible operation, easy mainte-nance, small footprint and so on. The paper introduces the process principle, the key equipment, theprocess characteristics and applicability. The process is applied to the large-volume stormwater treatmentof the Marquette-Lez-Lille sewage plant in Lille, France. The effluent can meet the required standard andthe treated rainwater is effectively used for irrigation.
出处 《中国给水排水》 CAS CSCD 北大核心 2017年第22期111-115,共5页 China Water & Wastewater
关键词 ActifloTurbo 微砂 暴雨水 舍流制溢流污水 加重絮凝 水力旋流器 Actiflo Turbo mircro-sand stormwater combined sewage overflow ballas-ted floc hydrocyclone
  • 相关文献

参考文献1

二级参考文献8

  • 1龚卫俊,郑燕,吴志超.ACTIFLO高效沉淀工艺用于污水处理[J].中国给水排水,2005,21(10):104-106. 被引量:16
  • 2Victoria P,Claus P D. The ACTIFLO method[ J]. Water Sci Technol, 1998,37 ( 1 ) :269 - 275.
  • 3Nicolas Le Poder,Patrick Binot. Treatment of combined sewer overflow (CSO) with high speed microsand settling [A]. WEF CONFERENCE "New and Emerging Environmental Technologies and Products Conference for Wastewater Treatment and Storm Water Collection" [ C ]. USA : WEF, 1995.
  • 4Sampley W E, Sullivan W D. No longer under the weather - Bremerton adopts an effective combined sewer overflow control solution [ J ]. Pollut Eng,2002, ( 5 ) :24 - 27.
  • 5Keller John, Kobylinski A, Hunter G L, et al. Actiflo: a year' s worth of operating experience from the largest SSO System in the US[ A]. Proceedings of the Water Environment Federation[C]. USA : WEFTEC ,2005.
  • 6Ponist J B, Scheiter D. Ballasted high rate clarification process removes city of Greenfield, Indiana as a CSO community [ EB/OL ]. http ://www. krugerusa. com/eib/ kryger/1/CB80vc22c0dmlu663. Zuzhby. pdf, 2010 - 03 -21.
  • 7李天琪.Actiflo微砂加重絮凝高效沉淀工艺设计介绍[J].给水排水,2009,35(4):11-13. 被引量:16
  • 8罗启达,周克明,陈伟,孙家熊.ACTIFLO——一种新型高效水处理澄清工艺[J].净水技术,2004,23(1):38-41. 被引量:19