摘要
地下综合管廊由标准段与节点组成。管廊节点作为管廊整体的一个重要组成部分,在管廊系统中扮演管线的"十字路口"角色,其中节点主要分为上出线节点和下出线节点。六盘水地下综合管廊主要采用下出线节点的结构形式。送排风风口均安装在节点-1层底板上,电力舱与热力舱均采用机械排风、自然进风的形式进行平时通风或者事故通风,燃气舱采用机械送风、机械排风的形式进行通风,在送风节点还有疏散通道与送风风口合用的多用途风口,针对管廊的地面送排风风口进行设计与分析。
The underground utility tunnel is composed of standard section and joints. As an important part of utility tunnel, the joints play the role of the pipeline ' crossroads' , of which the joints are divided into upper outlet joint and lower outlet joint. Liupanshui utility tunnel mainly applies lower outlet joint. The air outlet opening is installed on the ground of B1. And the power module and thermal module adopt the type of mechanical exhaust and natural air supply for ordinary or accident ventilation, and gas module applies mechanical exhaust and air supply for ventilation. There are multipurpose air openings for evacuation passage and air supply outlet. The design and analysis for ground stainless air outlet of utility tunnel are discussed.
作者
向先峰
李寅
蒲鸿征
来俊杰
吴真
陈博
XIANG Xianfeng;LI Yin;PU Hongzheng;LAI Junjie;WU Zhen;CHEN Bo(China Construction Second Engineering Bureau Ltd. , Beijing 100160, China)
出处
《施工技术》
CAS
北大核心
2017年第21期22-25,93,共5页
Construction Technology
基金
中国建筑第二工程局有限公司课题立项:城镇综合管廊关键施工技术研究(CSCEC2B-2015-K-03)
关键词
地下工程
综合管廊
通风
送排风口
施工技术
underground
comprehensive utility tunnel
ventilation
air outlet
construction