摘要
通过氨压缩机低压缸性能试验过程中出现出口侧振动值增大的现象,对其进行原因分析,提出相应措施,并试车成功,杜绝此类事故的再次发生。
pressure cylinder During performance test of ammonia compressor, it's found that vibration at the increased. Corresponding measures were taken after analyzing the reasons, the succeeded, and vibration never happened again.
出处
《大氮肥》
CAS
2017年第5期346-347,共2页
Large Scale Nitrogenous Fertilizer Industry
关键词
氨压缩机组
低压缸
隔板
真空度
ammonia compressor
low pressure cylinder
baffle
vacuum degree