期刊文献+

三维彩色能量多普勒超声对胎盘植入的诊断价值研究 被引量:20

Value of three dimensional color power Doppler ultrasound in diagnosis of placenta accrete
下载PDF
导出
摘要 目的:探讨三维彩色能量多普勒超声(three-dimensional color power Doppler ultrasound,3D-PDU)立体重建技术对胎盘植入的诊断价值。方法:收集65例可疑胎盘植入患者作为研究对象,均进行3D-PDU检查,并将3DPDU所得诊断结果与"金标准"(临床和/或病理诊断)进行比较。结果:3D-PDU检查与"金标准"诊断结果比较无显著差异(P=0.754),2种诊断方法的吻合度具有一致性(Kappa=0.661,P<0.001)。结论:3D-PDU与三维立体重建技术相互结合,可更直观、形象地显示病变处立体结构、血流灌注情况、血管空间位置情况,并能够提供量化指标,可有效判断胎盘植入深度、面积,对胎盘植入早期诊断及治疗方案制订、预后评估均具有重要意义。 bObjective To explore the diagnostic value of three-dimensional color Doppler ultrasonography(3 D-PDU) threedimensional reconstruction technique for placenta accrete.Methods Totally 65 cases of suspected patients with placenta implantation underwent 3 D-PDU examination, then the examination results were compared with those by clinical or pathological method, and the results by clinical or pathological method were used as the gold standard.Results There were no significant differences between the results by 3 D-PDU and the gold standard(P =0.754), and there was consistency between the two methods(Kappa =0.661,P0.001).Conclusion 3 D-PDU combined with 3 D reconstruction technique contributes to displaying lesion structure, blood perfusion and etc and provides quantitative indexes to determine the depth and size of the accreted placenta, and thus is of great significance for the early diagnosis and treatment planning of the placenta accrete.
出处 《医疗卫生装备》 CAS 2017年第11期65-68,89,共5页 Chinese Medical Equipment Journal
基金 广东省自然科学基金研究团队项目(2015A030312013) 镇江市重点研发计划面上项目(SH2015079)
关键词 三维彩色能量多普勒超声 胎盘植入 病理 诊断 立体重建技术 3D-PDU placenta accrete pathology diagnosis stereoscopic reconstruction technique
  • 相关文献

参考文献7

二级参考文献54

  • 1陈争春,蒋健穗,黄春玲.超声显像胎盘植入21例分析[J].中国误诊学杂志,2009,9(3):693-694. 被引量:12
  • 2Raine-Fenning NJ, Nordin NM, Ramnarine KV, et al .Determin- ing the relationship between three-dimensional power Doppler data and true blood flow characteristics : an in-vitro flow phantom experiment [ J ]. Ultrasound Obstet Gynecol , 2008,32 (4) : 540-550.
  • 3Raine-Fenning NJ, Nordin NM, Ramnarine KV, et al. Evaluation of the effect of machine settings on quantitative three-dimensional power Doppler angiography: an in-vitro flow phantom experiment [J ]. Ultrasound Obstet Gyneeol , 2008,32 (4) : 551-559.
  • 4Raine-Fenning NJ, Ramnarine KV, Nordin NM ,et al. Quantifica- tion of blood perfusion using 3D power Doppler: an in-vitro flow phantom study[J]. JPCS, 2004, 1 : 181-186.
  • 5Dubiel M, Hammid A, Breborowicz A ,et al. Flow index evaluation of 3-D volume flow images: An in vivo and in vitro study [J]. Ultrasound Med Biol,2006,32 (5) : 665-671.
  • 6Rovas L, Sladkevicius P, Strobel E ,et al. Intraobserver and interobserver reproducibility of three-dimensional gray-scale and power Doppler ultrasound examinations of the cervix in pregnant women. [J ]. Ultrasound Obstet Gynecol, 2005,26 (2) : 132-137.
  • 7Raine-Ferming NJ, Campbell BK, Clewes JS, et al. The reliability of virtual organ computer-aided analysis (VOCAL) for the semiquantification of ovarian, endometrial and subendometrial perfusion [ J ]. Ultrasound Obstet Gynecol, 2003,22 (6) : 633-639.
  • 8Merce LT, Barco MJ, Bau S. Reproducibility of the study of placental vascularization by three-dimensional power Doppler [J].J Perinat Med , 2004,32 (3) : 228-233.
  • 9Merce LT, Barco M J, Bau S, et al. Assessment of placental vascularization by three-dimensional power Doppler "vascular biopsy" in normal pregnancies [ J ]. Croat Med J, 2005,46 (5) : 765-771.
  • 10Zalud I, Shaha S. Evaluation of the utero-placental circulation by three-dimensional Doppler ultrasound in the second trimester of normal pregnancy [J]. J Matem Fetal Neonatal Med, 2007,20 (4) : 299-305.

共引文献127

同被引文献163

引证文献20

二级引证文献94

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部