期刊文献+

Error analysis and Stokes parameter measurement of rotating quarter-wave plate polarimeter 被引量:1

Error analysis and Stokes parameter measurement of rotating quarter-wave plate polarimeter
下载PDF
导出
摘要 In this paper, we present a simple Stokes parameter measurement method for a rotating quarter-wave plate polarimeter. This method is used to construct a model to describe the principle of how the magnitudes of errors influence the deviation of the output light Stokes parameter, on the basis of accuracy analysis of the retardance error of the quarter-wave plate, the misalignment of the analyzing polarizer, and the phase shift of the measured signals, which will help us to determine the magnitudes of these errors and then to acquire the correct results of Stokes parameters. The method is validated by the experiments on left-handed circularly polarized and linear horizontal polarization beams. With the improved method, the maximum measurement deviations of Stokes parameters for these two different polarized states are reduced from 2.72% to 2.68%, and from 3.83% to 1.06% respectively. Our results demonstrate that the proposed method can be used as a promising approach to Stokes parameter measurement for a rotating quarter-wave plate polarimeter. In this paper, we present a simple Stokes parameter measurement method for a rotating quarter-wave plate polarimeter. This method is used to construct a model to describe the principle of how the magnitudes of errors influence the deviation of the output light Stokes parameter, on the basis of accuracy analysis of the retardance error of the quarter-wave plate, the misalignment of the analyzing polarizer, and the phase shift of the measured signals, which will help us to determine the magnitudes of these errors and then to acquire the correct results of Stokes parameters. The method is validated by the experiments on left-handed circularly polarized and linear horizontal polarization beams. With the improved method, the maximum measurement deviations of Stokes parameters for these two different polarized states are reduced from 2.72% to 2.68%, and from 3.83% to 1.06% respectively. Our results demonstrate that the proposed method can be used as a promising approach to Stokes parameter measurement for a rotating quarter-wave plate polarimeter.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期242-247,共6页 中国物理B(英文版)
基金 Project supported by the National High Technology Research and Development Program of China(Grant No.2015AA123702) the National Natural Science Foundation of China(Grant No.61505222)
关键词 POLARIZATION stokes parameter detection POLARIMETER polarization stokes parameter detection polarimeter
  • 相关文献

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部