采用改性PVC填料的生物膜法污水处理实验研究 被引量:3

Experimental Study on Biofilm Sewage Treatment with Modified PVC Filler
下载PDF
导出
摘要 采用单级生物接触氧化池和PVC改性填料处理人工配置的原水,通过改变原水COD浓度、温度、气液比、进水流量,对填料的挂膜时间和工艺的运行效能进行分析,获得较好的工况参数。结果表明:有机负荷和温度均会对挂膜时间产生影响,原水浓度越高,挂膜完成时间越短;环境温度为30℃左右时,挂膜时间较短;采用好氧生物接触法对污水进行处理时,必须要有适量的溶解氧供给;对本研究所示的单级生物接触氧化池,建议控制气液比为10∶1。 The single-stage biological contact oxidation tank and PVC modified filler were used to treat the sewage. By analyzing biofilm formation and operating efficacy by changing the sewage concentration,temperature, gas-liquid ratio, influent flow, and we finally get better working conditions parameters. Results shows that the sewage concentration and temperature have influence on the biofilm formation,and the higher sewage 's concentration is,the shorter biofilm formation is;biofilm formation is short when temperature is about 30 ℃. It is necessary to have an appropriate amount of gas-liquid ratio. When the aerobic biological contact method is used to treat the sewage.For the single-stage biological contact oxidation tank shown in this paper,it is recommended to control the gas-water ratio to 10∶ 1.
出处 《重庆理工大学学报(自然科学)》 CAS 2017年第11期135-138,共4页 Journal of Chongqing University of Technology:Natural Science
基金 全军后勤科研项目(BY114C006)
关键词 单级生物接触氧化池 PVC改性填料 工况参数 single-stage biological contact oxidation tank PVC modified filler working conditions parameters