摘要
南京市综合应急救援训练基地综合楼按三星级绿色建筑标准设计。本文详细介绍了该工程中暖通空调系统的设计内容及绿建节能设计要点。通过将地源热泵空调系统与变频多联式空调系统相结合,既满足了冬、夏季不同功能房间对空调系统的使用要求,又能实现过渡季节的全新风工况运行,从而充分利用能源、降低能耗,达到三星级绿色建筑的评价要求。
ANanjing integrated emergency rescue training base complex building is designed by three-star green building standard. This paper introduces the design content of hvac system and the key points of green building energy saving design. By putting a ground source heat pump air conditioning system with variable frequency split type air conditioning system, satisfy the diferent function rooms in winter and summer for the use of air conditioning system requirements, and can realize transition season full fresh air operation, so as to make full use of energy, reducing energy consumption, three-star green building assessment requirements.
出处
《供热制冷》
2017年第12期60-63,共4页
Heating & Refrigeration
关键词
绿色建筑
地源热泵
变频多联
新风
节能
Green building, Ground source heat pump, Frequency conversion multigang, Fresh air,Energy saving