摘要 以某240m高单筒式钢筋混凝土烟囱为例,通过ABAQUS建立模型,计算了自重荷载、风荷载、温度作用对烟囱的单独作用和组合作用效应。分析得知烟囱的顶点最大位移、承载能力均满足规范要求,烟囱裂缝除局部筒壁最大裂缝宽度不满足规范要求外,其余部分均满足要求。根据有限元计算结果,需对烟囱筒壁出现的损伤进行修复加固,以提高烟囱刚度以避免风振效应,消除烟囱使用过程中的安全隐患。 Taking an example of 240 meters high single tube reinforced concrete chimney, a model is es-tablished through the finite element analysis program ABAQUS to analyze the effect of gravity, wind and tempera-ture which work respectively and simultaneously. The results show that the maximum displacement of the top ofchimney, bearing capacity can meet the requirements of the specification. The maximum crack width of thechimney also meets the design specification except for the body of local chimney wall. According to the results ofthe finite element calculation, the chimney~ damaged areas need repair and reinfbrcement to improve the rigidi-ty, avoiding the wind vibration effect, and eliminate the potential safety hazard.
作者 张宏 卢亦焱
出处 《佳木斯大学学报(自然科学版)》 CAS 2017年第6期944-949,共6页 Journal of Jiamusi University:Natural Science Edition
基金 湖北省技术创新专项重大项目(2016AAA025)
关键词 单筒式烟囱 有限元分析 修复加固 single tube reinforced concrete chimney finite element analysis repair and reinforcement
  • 相关文献

参考文献11

二级参考文献41

  • 1李会民,李华明.砖烟囱震害破坏特征及抗震防灾系统研究[J].特种结构,1996,13(3):60-62. 被引量:1
  • 2刁学优.混凝土结构盐酸腐蚀事故鉴定与分析[J].建筑结构,2006,36(12):49-51. 被引量:3
  • 3张开.聚氯乙烯[G]//杨光启,侯祥麟.化工.北京:中国大百科全书出版社,1987:360.
  • 4洪乃丰.氯盐引起的钢筋锈蚀及耐久性设计考虑[G]//中国工程院水利建筑学部.混凝土及耐久性设计与施工.北京:中国建筑工业出版社,2004.
  • 5GB50164--92混凝土质量控制标准[S].北京:中国建筑工业出版社,1992.
  • 6GBJ51-83烟囱设计规范[S].北京:冶金工业出版社,1983、
  • 7GB50204--2002混凝土结构工程施工质量验收规范[S].北京:中国建筑工业出版社,2002.
  • 8GB50046--95工业建筑防腐蚀设计规范[S].北京:中国计划出版社.1995.
  • 9DL5022--93火力发电厂土建结构设计技术规定[S].北京:水利电力出版社,1993.
  • 10GB50051-2002烟囱设计规范[S].北京:中国计划出版社,2002.

共引文献27

同被引文献10

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部