期刊文献+

对自承重墙高厚比验算几个问题的分析

Analysis on the Calculation of Height to Thickness Ratio of Non-bearing Masonry Walls
下载PDF
导出
摘要 自承重墙广泛应用于建筑工程等项目中,高厚比验算对保障墙体的安全起着重要的作用。论文介绍了墙体高厚比验算的规定,重点对自承重墙计算高度的计算进行了分析,并给出了墙体在给定条件下允许计算高度和允许砌筑高度数值,最后提出了增加墙体允许砌筑高度的措施。 Non-bearing masonry wall is widely used in construction projects and other proj ects,the calculation of height to thickness mtioplays an important role in ensuring the safety of the wall. This paper introduces the calculation of height to thickness ratio of the wall, and analyzes the calculation of the height of non-bearing masonry wall, and gives the allowable calculation height and the masonryallowable height of the wall under certain conditions. Finally, the measures to increase the allowableheight of wall masonry are put forward.
出处 《工程建设与设计》 2017年第23期68-71,共4页 Construction & Design for Engineering
关键词 自承重墙 高厚比计 算高度 non-bearing masonry wall height to thickness ratio height calculation