摘要
对供热系统中管道敷设形式分析,并探讨了固定墩的计算方法,最后针对不同固定墩形式进行对比,得出要是管道推力相对小,则适宜应用矩形固定墩形式,要是管道推力相对大,则适宜应用板凳形固定墩形式。
The analysis of the form of pipe laying in the heating system, and discusses the calculation method of the fixed pier, compares different forms of fixed pier, that if the pipeline thrust is relatively small, is suitable for the application of rectangular fixed pier, if the pipeline thrust is relatively large, is suitable for the application of fixed bench shaped pier form.
出处
《山西建筑》
2017年第34期125-126,共2页
Shanxi Architecture
关键词
直埋敷设
固定墩
设计
direct buried laying, fixed pier, design