期刊文献+

PET心肌灌注显像及其定量分析的研究进展 被引量:4

The research progress of myocardial perfusion and its quantitative analysis with PET
原文传递
导出
摘要 近些年,随着PET/CT设备及心脏正电子示踪剂的快速发展,PET心肌血流灌注显像(PET-MPI)在临床上的作用逐渐加强.心肌血流灌注定量分析提供了心肌血流的客观评价标准,可以客观、准确地发现早期灌注异常,准确地对冠心病进行危险分层、预后评价和客观判断治疗效果,为冠心病临床诊治、心脏的生理和病理生理学领域的活体无创性研究提供重要信息.笔者就PET-MPI及其定量分析的研究进展进行综述. With the improvement of positron emission computed tomography (PET/CT) devices and the availability of cardiac positron tracers, the clinical interest in myocardial perfusion PET(PET-MPI) has increased over the years. PET-MPI enables noninvasive and accurate quantification of myocardial blood flow(MBF) and myocardial flow reserve(MFR), making it possible to enhance detection of early stages of vascular dysfunction, improve risk stratification of coronary heart disease, guide clinical management, evaluate efficacy and prognosis. The aim of this narrative review was to summarize the progress of cardiac PET for myocardial perfusion and its quantitative analysis.
出处 《国际放射医学核医学杂志》 2017年第6期423-429,共7页 International Journal of Radiation Medicine and Nuclear Medicine
基金 天津市卫生和计划生育委员会科技基金重点攻关项目(16KG145) 天津市滨海新区卫生和计划生育委员会科技项目(2015BWKL002)
关键词 冠状动脉疾病 正电子发射断层显像术 体层摄影术 X线计算机 心肌血流灌注显像 心肌血流量 Coronary disease Positron-emission tomography Tomography,X-ray computed Myocardial perfusion imaging Myocardial blood flow
  • 相关文献

参考文献4

二级参考文献145

  • 1朱永胜,张军,George Athanassopoulos,周晓东,钱蕴秋,George Karadasakis,朱霆.经胸彩色多普勒检测冠心病患者冠状动脉左前降支和右冠状动脉远端血流储备[J].中华心血管病杂志,2005,33(9):801-805. 被引量:4
  • 2何祚祥.放射性核素显像在冠心病诊断中的临床应用[J].中国医刊,2006,41(1):21-24. 被引量:5
  • 3Gould KL, Lipscomb K. Effects of coronary stenoses on coronary flow reserve and resistance. Am J Cardiol, 1974, 34( 1 ): 48-55.
  • 4Heller LI, Cares C, Popma J, et al. Intracoronary Doppler assess- ment of moderate coronary artery disease: comparison with 2--T1 imaging and coronary angiography. FACTS Study Group. Circula- tion, 1997, 96(2 ): 484-490.
  • 5Nagel E, Thouet T, Klein C, et al. Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic -so- nance in patients after stent deployment. Circulation, 2003, 107 ( 13): 1738-1743.
  • 6Lautamaki R, George RT, Kitagawa K, et al. Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: validation in a canine model of coronary artery stenosis. Eur J Nucl Med Mol hnaging, 2009, 36(4): 576-586.
  • 7Schindler TH, Zhang XL, Prior JO, et al. Assessment of intra-and interobserver reproducibility of rest and cold pressor test-stimulated myocardial blood flow with -3N-ammonia and PET. Eur J Nucl Med Mol Imaging, 2007, 34( 8 ): 1178-1188.
  • 8Choi Y, Huang SC, Hawkins RA, et al. Quantification of myocardial blood flow using -3N-ammonia and PET: comparison of tracer mod- els. J Nucl Med, 1999, 40(6): 1045-55.
  • 9Schelbert HR. Quantification of myocardial blood flow: what is the clinical role?. Cardiol Clin, 2009, 27( 2 ): 277-289.
  • 10Schindler TH, Schelbert HR, Quercioli A, et al. Cardiac PET imag- ing for the detection and monitoring of coronary artery disease and microvascular health. JACC Cardiovasc Imaging, 2010, 3 (6): 623- 640.

共引文献9

同被引文献28

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部