摘要 目的 :研究不同材质球帽附着体对下颌种植覆盖义齿固位力的影响。方法 :实验分为A组(钛球/钛帽组)、B组(钛球/贵金帽组),每组3个试件。制作标准下颌无牙颌模型,在双侧尖牙区植入4.8×10 RN SP种植体各1颗,常规制作下颌全口义齿,连接附着体。进行5000次摘戴循环,每200次摘戴测试固位力。采用SPSS 13.0软件包对所得数据进行组间比较,并在实验初始、终末期采用扫描电镜观察阳性结构的表面形态变化。结果:A组固位力从(27.00±0.16)N衰减到(4.18±0.03)N,B组固位力从(21.58±0.06)N衰减到(19.15±0.06)N,A组固位力衰减显著大于B组。实验终末,A组球状立体结构严重破坏,而B组球状立体结构光滑清晰。结论:球帽附着体下颌种植覆盖义齿的固位力随着摘戴次数的增加而逐渐降低,其固位力衰减与阳性结构表面破坏有关,贵金属材质抗疲劳性较好。 PURPOSE: To investigate the effect of ball attachments with different materials on retention of mandibular implant supported overdenture. METHODS: The experimental groups were divided into group A (titanium ball / titanium cap group) and group B (titanium ball / golden cap group), each group had 3 samples. A standard mandibular edentulous model was made, and the implants (4.8*10 RN SP) were embedded in the bilateral canine region. Mandibular complete dentures were made routinely and the attachments were attached. Five thousand times of insertion-separation cycles were carried out. After 200 times of cycles, the retention force was tested. The difference between 2 groups was compared by using SPSS 13.0 software package. The change of positive structure surface morphology was observed under scanning electron microscope at the beginning and the end of the experiment. RESULTS: The retention force of group A decreased from (27.00±0.16) N to (4.18±0.03) N, and the retention force of group B decreased from (21.58±0.06) N to (19.15±0.06)N. Decay of retention of group A was significantly greater than that of group B. At the end of the experiment, the globular structure of group A was severely broken, while a smooth and clear spherical structure was displayed in group B. CONCLUSIONS: The retention of mandibular implant supported overdenture decreases with the increase of insertion-separation times. The decay of retention force is related to destruction of positive structure surface. The fatigue resistance of the precious metal material is better.
作者 余文珺 何嘉菁 刘韫嘉 焦婷 SHE Wen-jun;HE Jia-jing;LIU Yun-jia;JIAO Ting(Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine,Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology,National Clinical Research Center of Stomatology. Shanghai 200011;Department of Prosthodontics, Shanghai Stomatological Hospital. Shanghai 200011, China)
出处 《上海口腔医学》 CAS CSCD 2017年第6期586-589,共4页 Shanghai Journal of Stomatology
基金 上海市科学技术委员会资助项目(14411964200) 上海市卫生局资助项目(2011120)
关键词 种植覆盖义齿 钛球/钛帽附着体 钛球/贵金帽附着体 固位力 Implant supported overdenture Titanium ball / titanium cap attachment Titanium ball / golden cap attachment Retention
  • 相关文献

参考文献2

二级参考文献27

  • 1AI-Ghafli SA, Michalakis KX, Hirayama H,et al. The in vitro effect of different implant angulations and cyclic dislodgement on the re- tentive properties of an overdenture attachment system [J]. J Prosthet Dent, 2009, 102 (3) : 140-147.
  • 2Ruthkunas V, Mizutani H,Takahashi H. Influence of attachment wear on retention of mandibalar overdenture [J]. J Oral Rehabil, 2007, 34 (1):41-51.
  • 3Sadig W. Acomparative in vitro study on the retention and stability of implant-supported overdentures [J].Quintessence Int, 2009,40 (4) : 313-319.
  • 4Mericske-Stern R. Overdentures with roots or implants for elderly patients:A comparison[J].Journal of Prosthetic Dentistry,1994,(05):543-550.
  • 5Wrstmann B,Budtz-Jφrgensen E,Jepson N. Indications for removable partial dentures:A literature review[J].International Journal of Prosthodontics,2005,(02):139-145.
  • 6Kaufmann R,Friedli M,Hug S. Removable dentures with implant support in strategic positions followed for up to 8 years[J].Irit J Prosthodont,2009,(03):233-241.
  • 7Doukas D,Michelinakis G,Smith PW. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants:6-month fatigue retention values[J].International Journal of Prosthodontics,2008,(02):152-154.
  • 8Setz I,Lee SH,Engel E. Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible:an in vitro study[J].Journal of Prosthetic Dentistry,1998,(03):323-329.
  • 9Petropoulos VC,Smith W. Maximum dislodging forces of implant overdenture stud attachments[J].International Journal of Oral & Maxillofacial Implants,2002,(04):526-535.
  • 10Van Kampen F,Cune M,Van der Bilt A. Retention and postinsertion maintenance of bar-clip,ball and magnet attachments in mandibular implant overdenture treatment:an in vivo comparison after 3 months of function[J].Clinical Oral Implants Research,2003,(06):720-726.

共引文献3

同被引文献37

引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部