期刊文献+

48万吨/年气体分馏装置脱丙烷塔运行及优化 被引量:1

Operation and optimization of stripper tower in 480 thousand tons/year gas separation unit
下载PDF
导出
摘要 本文对脱丙烷塔压力热旁路控制系统原理进行了论述,分析了扬子石化炼油厂48万吨/年气体分馏装置脱丙烷塔运行情况,通过改变热旁路控制方案,达到优化脱丙烷塔运行目的,保证了产品质量合格率。 This paper the Depropanizator thermal pressure bypass control system principle are discussed, analyzed the 480 thousand tons/year gas fractionation unit in Yangzi Petrochemical refinery and the operation condition of propane, by changing heat bypass control scheme to optimize the depropanizer operation to ensure the qualification rate of product quality.
作者 叶辉
出处 《石化技术》 CAS 2017年第12期44-44,共1页 Petrochemical Industry Technology
关键词 精馏塔 压力调节 优化 distillation tower pressure regulation optimization
  • 相关文献

参考文献1

二级参考文献6

  • 1HARTMAN E L, BARLETTA T. Reboiler and Condenser Operating Problems[J]. ptq, 2003, (2): 52-55
  • 2RIGGS J B. Improve Distillation Column Control[J]. Chem Eng Progress, 1998,94(10) : 31-47
  • 3SCHNEIDER D F, HOOVER M C. Practical Process Hydraulics Considerations[J]. Hydroc Proc, 1999,78(8): 47-53
  • 4ANDREW W S. Effectively Control Column Pressure[J]. CEP, 2001, 97 (1): 39-48
  • 5KISTER H Z. Distillation Operation[M]. New: McGraw-Hill 1989: 528-534
  • 6FRIEDMAN Y Zak. Condenser Hot Vapor Bypass Control[J]. Hydroc Proc,2008,87(6) :150