摘要 目的 应用Spinocath导管行连续蛛网膜下隙阻滞 ,观察麻醉效果、血液动力学变化及术后可能的并发症。方法 择期行下腹部及下肢手术病人 2 0例 ,选L2~ 3 或L3~ 4间隙行连续蛛网膜下隙阻滞 ,首量 0 5 %的重比重布比卡因 1~ 2ml。术中每隔 6 0~ 90分钟追加 0 5~ 1ml,术后随访 72小时。结果 Spinocath导管连续蛛网膜下隙阻滞可以在手术的过程中连续提供满意的镇痛和肌松 ,对循环和呼吸的影响小。结论 Spinocath导管连续蛛网膜下隙阻滞血液动力学稳定 ,并发症少 。 Objective To observe the anesthesia,hemodynamics and postoperative complications during continuous spinal anesthesia with spinocath catheter.Methods Continuous spinal anesthesia was performed at L 2 3 or L 3 4 interspace in twenty patients undergoing lower abdomen or lower limbs operation.1 2ml of 0 5% hyperbaric bupivacaine was initially bolused and supplemented with 0 5 1ml every 60 90min during the operation.The patients were followed for 72 hours after operation for possible side effects related to anesthesia.Results Continuous spinal anesthesia with spinocath catheter provided a perfect analgesia, satisfactory muscle relaxation during operation with a little circulatory and respiratory effects.Conclusion Continuous spinal anesthesia with spinocath catheter may be suitable for the operations below the umbilicus because of its complete anesthesia, stable hemodynamics and little complication. [
出处 《临床麻醉学杂志》 CAS CSCD 2002年第8期414-415,共2页 Journal of Clinical Anesthesiology
关键词 临床应用 SPINOCATH导管 蛛网膜下隙阻滞 Spinocath catheter Subarachnoid block
  • 相关文献

参考文献5

  • 1[1]Mollmann M. Spinocath, a new approach to continuous spinal anesthesia-preliminary result of a multicenter trail. International Monitor on Regional Anaesthesia, 1996, 8:74.
  • 2[2]Favarel-Garrigues JF, Sztark F, Petitjean ME, et al. Hemo dynamic effects of spinal anesthesia in the elderly: single dose versus titration through a catheter. Anesth Analg, 1996, 82:312-316.
  • 3[3]Hurley RJ, Lambert DH. Continuous spinal anesthesia with a microcathter technique. Preliminary experience. Anesth Analg, 1990, 70:97-102.
  • 4[4]Rigler ML, Drasner K, Krejcie TC, et al. Cauda equina syndrome after continuous spinal anesthesia. Anesth A nalg, 1991,72:275-281.
  • 5[5]Denny N, Master R, Pearson D, et al. Postdural puncture headache after continuous spinal anesthesia. Anesth Analg,1987, 66: 791-794.