期刊文献+

HPLC法测定行连续性肾脏替代治疗超滤液中奥硝唑的含量及其应用 被引量:3

HPLC determination and application of ornidazole in the ultra-fi ltrate liquid of the continuous renal replacement therapy(CRRT)
下载PDF
导出
摘要 目的建立HPLC分析方法测定危重症患者行连续性肾脏替代治疗超滤液中奥硝唑的含量,监测连续性肾脏替代治疗对抗生素类药物代谢的影响,为临床个体化给药提供依据,合理使用抗生素。方法色谱柱为Agilent ZORBAX SBC_(18)(4.6mm×150mm,5μm);流动相为甲醇-水(30:70,V/V),流速为1.0m L/min;检测波长为318nm;柱温为25?C;进样量为10μL,运行时间9min。结果奥硝唑在2.00~40.00μg/m L范围内与其峰面积线性关系良好(r=1.000),平均回收率为98.84%(n=9),RSD为0.87%。结论该方法简单、快速,结果准确且重复性好,可用于连续性肾脏替代治疗超滤液中奥硝唑含量的测定,为奥硝唑的临床研究提供可靠的分析方法。 Objective To establish an HPLC method for the determination of omidazole in the ultra-filtrate liquid of the continuous renal replacement therapy (CRRT) for critically ill patients,to monitor the effects of CRRT ultra-filtrate liquid on the metabolism of antibiotics,and to provide a basis for the individualized medication and reasonable use of antibiotics.Methods An agilent ZORBAX SB-C18 (4.6mm×150mm,5μm) was chosen for the analysis.The mobile phase consisted of methanol and water (30:70,V/V).The flow rate was 1.0mL/min with the detection wavelength of 318nm,the column temperature was 25 ℃,the injection volume was 10μL,and the running time was 9min.Results A good linear correlation of omidazole was observed within the range of 2.00~40.00μg/ mL (r=l.000).The average recovery rate of ornidazole was 98.84% (n=9),with RSD of 0.87%.Conclusion This method was rapid,convenient,accurate,robust and suitable for the determination of ornidazole in CRRT ultra-filtrate liquid.A reliable analytical method was provided for the clinical study of omidazole.
出处 《中国抗生素杂志》 CAS CSCD 北大核心 2017年第11期963-966,共4页 Chinese Journal of Antibiotics
基金 北京药学会基金2014年研究项目
关键词 连续性肾脏替代治疗 抗生素类药物 奥硝唑 HPLC Continuous renal replacement therapy Antibiotics Omidazole HPLC
  • 相关文献

参考文献12

二级参考文献111

共引文献89

同被引文献41

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部