期刊文献+

侧吹风对建筑外立面窗溢流流动的影响

Influence of the side wind on the flow behavior of the window plume along the exterior wall
下载PDF
导出
摘要 以高层宾馆为例,通过理论分析和数值模拟的方法分析不同火源功率、不同侧吹风风速作用下建筑外立面窗溢流的温度分布、倾斜角,研究窗溢流的流动特性。通过理论分析得到了侧吹风作用下窗溢流倾斜角的计算式。倾斜角的模拟值与计算式的预测值符合较好。 Taking a high-rise building hotel as example, by thcoreti cal analysis and numerical simulation, the l~:mperature dislribution and inclination angle of lhe window plume along the exlerior wall of the building were studied. The flow behavior of window plume was discussed. The calculation formula of inclination angle of the window jet plume was obtained by theorelical analysis. The simula tion results and the calculation results of inclination angle were in good agreement.
出处 《消防科学与技术》 CAS 北大核心 2017年第11期1518-1520,共3页 Fire Science and Technology
基金 北京市自然科学基金-北京市科学技术研究院联合资助项目(L140002)
关键词 侧吹风 窗溢流 倾斜角 建筑火灾 side wind window plume inclination angle buildingfire
  • 相关文献

参考文献4

二级参考文献31

  • 1姜玉曦,任玉新,刘秋生.室内火灾中外部燃烧现象的数值模拟[J].火灾科学,2006,15(2):92-101. 被引量:7
  • 2朱杰,霍然,付永胜.超高层建筑火灾防排烟研究[J].消防科学与技术,2007,26(1):54-57. 被引量:44
  • 3Chen Haixiang, Liu Naian, Chow Wan Ki. Wind effect on smokemotion and temperature of ventilation-controlled fire in a two-ventcompartment[J ]. Building and Environment,2009,( 44 ): 2521 -2526.
  • 4Chow W K. Building fire safety in the far east[J]. ArchitecturalScience Review,2005 ,(4) : 85 - 94.
  • 5NP'PA 92B,Guide for smoke management systems in malls,atriaand large areas[S].
  • 6Hansell G O, Morgan H P. Design approaches for smoke control inatrium buildings[R]. Garston: Building Research Report, BR258,Building Research Establishment, 1994.
  • 7C'ox Ci. Combustion fundamentals of fire[M]. London: AcademicPress Limited, 1995.
  • 8Yokoi S. Upward convection current from a burning wooden house.The use of models in fire research[R], DC: National Academy ofSciences, National Research Council, Washington, 1961.
  • 9Ycimaguchi J,Tanaka T. Temperature profiles of window jet plumeJ Fire Science and Technology, 2005 ,24(1): 17 - 38.
  • 10Chow C L, Chow W K. Heat release rate of accidental fire in a su-pertall building residential flat [ J ]. Building and Environment,2010,(45);1632-1640.

共引文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部