摘要
文章以乐亭国家基本气象站新型自动气象站蒸发传感器出现的故障为实例,分析了AG2.0超声波蒸发传感器出现故障的原因,根据蒸发传感器的系统结构及工作原理,阐述了故障排查方法和蒸发数据异常时的处理方法,并提出日常维护中应注意事项,以供台站应用参考。
Taking the malfunctions happened on the evaporator sensor of new automatic weather station in Laoting national basic meteorological station as an example,the reasons that caused the failures on AG2.0 ultrasonic evaporative sensor have been analyzed.According to the system structures and working principles of the evaporative sensor,the troubleshooting methods and the abnormal data processing when the data is abnormal have been expounded.Precautions of the daily maintenance have been proposed for station application reference.
出处
《气象水文海洋仪器》
2017年第4期110-113,120,共5页
Meteorological,Hydrological and Marine Instruments
关键词
新型自动站
蒸发传感器
故障排查方法
数据处理
维护注意事项
new automatic weather station
evaporator sensor
troubleshooting methods
data processing
maintenance precautions