期刊文献+

成人寰椎后弓部分结构测量及意义 被引量:4

Measurements of posterior arch of atlas and its significance
下载PDF
导出
摘要 目的获得成人寰椎后弓部分解剖参数,为后弓内固定钉板系统的设计提供依据。方法对60名成人(男30,女30)寰椎三维CT及40具干燥寰椎标本进行测量,测量指标有后结节中央及距中央5、10、15 mm处高度(矢状面垂直距离)及厚度(轴位垂直距离)、后弓水平面夹角、内侧面椎动脉沟半距、外侧面椎动脉沟半距,比较CT测量数据与标本测量数据有无差异。结果 CT测量:后结节中央高度为(9.48±0.95)mm,厚度为(7.80±1.60)mm,后弓夹角为(130.70±12.31)°,内侧面椎动脉沟半距为(11.08±1.28)mm,外侧面椎动脉沟半距为(20.13±1.53)mm;标本测量:后结节中央高度为(9.97±2.18)mm,厚度为(7.44±1.32)mm,后弓夹角为(135.07±9.59)°,内侧面椎动脉沟半距为(11.33±0.52)mm,外侧面椎动脉沟半距为(20.86±0.84)mm。CT测得内、外侧面椎动脉沟半距均小于标本测得数据,且差异有统计学意义。结论 CT资料可较好反映实体的解剖特征,解剖学测量可为临床实践提供有力参考。 Objective To acquire partial anatomical parameters of posterior arch of atlas, and to provide a reference for design of screw-plate fixation system. Methods A total of 60 3 D CT and 30 dry atlas specimens were used to measure anatomical data. The parameters included anterior-to-posterior thickness and superior-to-inferior height of the posterior ring of C1 at the midline as well as at 5 mm, 10 mm,15 mm lateral to the midline, angle of the posterior arch, the semi-distance of vertebral artery groove in inner surface and the semi-distance of vertebral artery groove in outer surface. The data gained from CTs and specimens was then compared. Results CTs measurement: The height of the center of posterior nodule was(9.48±0.95)mm, and the respective thickness was(7.80±1.60)mm. The angle of posterior arch was(130.70±12.31) °. The semi-distance of vertebral artery groove in inner surface and the semi-distance of vertebral artery groove in outer surface was(11.08 ± 1.28) mm and(20.13 ± 1.53) mm, respectively. Specimens measurement:The height and thickness of the midline was(9.97±2.18) mm and(7.44±1.32) mm, respectively. The angle of posterior arch was(135.07±9.59)°. The semi-distance of vertebral artery groove in inner and outer surface was(11.33±0.52)mm and(20.86±0.84)mm, respectively. The data of the semi-distance of vertebral artery groove gained from CTs was smaller than that measured from specimens with statistical difference. Conclusion Data measured from CT can present anatomical structure precisely and anatomical study is of referable significance in clinical practice.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2017年第6期610-614,共5页 Chinese Journal of Clinical Anatomy
关键词 寰椎 测量 解剖学 Atlas Measurement Anatomy
  • 相关文献

参考文献3

二级参考文献32

  • 1孙静宜,李世和.手术治疗寰椎椎动脉沟环所致的颈性眩晕(附8例报告)[J].颈腰痛杂志,1994,15(2):67-69. 被引量:7
  • 2刘彦,陈跃先.寰椎脱位的钢线内固定植骨术[J].中华外科杂志,1989,27(12):723-725. 被引量:6
  • 3陈鸿儒 杨克勤 张潭澄 等.颈椎骨测量在临床上的意义[J].中华骨科杂志,1982,2(1):23-23.
  • 4Farey ID, Nadkarni S, Smith N. Modified Gallic technique versus transarticular screw fixation in C1-C2 fusion. Clin Orthop Relat Res, 1999(359): 126-135.
  • 5Statham P, O'Sullivan M, Russell T. The Halifax Interlaminar Clamp for posterior cervical fusion: initial experience in the United Kingdom. Neurosurgery, 1993, 32(3): 396-399.
  • 6Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976), 2001, 26(22): 2467-2471,.
  • 7Suchomel P, Stulik J, Klezl Z, et al. Transarticular fixation of C1- C2: a multicentcr retrospective study. Acta Chir Orthop Traumatol Cech, 2004, 71(1): 6-12.
  • 8Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg, 1998, 88(4): 634-640.
  • 9Floyd T, Grob D. Translaminar screws in the atlas. Spine (Phila Pa 1976), 2000, 25(22): 2913-2915.
  • 10Donnellan MB, Sergides IG, Sears WR. Atlantoaxial stabilization using multiaxial C-1 posterior arch screws. J Neurosurg Spine, 2008, 9(6): 522-527.

共引文献56

同被引文献23

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部