用全自动电位滴定法测定复肥中的氯离子含量。通过与佛尔哈德法结果的比较,以及重复性和回收率的试验,证明此法可以应用于复肥中氯离子含量的测定,结果与佛尔哈德法相符。
Chloride ion content in compound fertilizer was determinated by automatic potentiometric titration.By comparing with the results of the Volhard method,repeatability and recovery test,this method was proved to be applied in determinate of chloride ion content in compound fertilizer.The result was consistent with the Volhard method.
出处
《浙江化工》
CAS
2017年第12期46-48,共3页
Zhejiang Chemical Industry
关键词
全自动电位滴定法
氯离子含量
佛尔哈德法
automatic potentiometric titration
chloride ion content
the Volhard method